25613-0-0309Page 10
Framing and Finishing
1. Choose unit location.
2. Frame in replace with a header across the top. It is important to
allow for nished face when setting the depth of the frame.
3. Attach replace to frame using adjustable nailing ange. Preset
depth to suit facing material (adjustable to 3/8", 1/2" or 3/4" depths).
Note: Fireplace must mount ush to facing material. If facing
material requires more depth than 3/4" mark and drill two
(2) 1/8" holes into replace side at appropriate depth. See
Figure 10.
4. Use (8) 1/2" hex-head screws supplied in hardware package,
to screw through slotted holes in drywall strip and then screw
into pre-drilled holes on replace side. Measure from face of
replace to face of drywall strip to determine nal depth.
Figure 8A
Vent Pipe Clearance
Note: Maintain one inch (1") of clearance around vertical vent
pipe. See Figure 9A. For horizontal vent, maintain a minimum 1"
clearance to the bottom and sides of the vent, and 3" clearance to
combustibles above the vent pipe. See Figure 9B.
Figure 9A
VENTPIPE
1"MINIMUM CLEARANCE AROUND VENT PIPE
USEOUTER
(4)FLANGES
FOR1/2”
DRYWALL
Figure 9B
INSTALLATION
2”X4”STUD
2”X4”BOTTOM
PLATE
FINISHEDWALL FINISHEDSURFACE
(TILE,ETC.)
TOPSTANDOFF
Figure 8B