Configuring the WAN Ports

4.Enter encapsulation ppp to select PPP encoding.

5.Enter no shutdown to keep the BRI interface enabled.

BRI Leased Frame Relay

1.Enter interface bri 0:<1 2>.<1-30>to acquire BRI Interface mode and select the BRI port and channel 1 or 2.

2.Enter encapsulation frame-relayto select Frame Relay encoding.

3.Enter no shutdown to keep the BRI interface enabled.

4.Enter frame-relaylmi-type <ilmi ansi q933a auto none> to select the Local Management Interface type.

5.Enter interface bri 0:<1 2>.<1-30>multi-pointto acquire BRI Sub-interface mode and select the BRI port, channel, and sub-interface.

6.Enter ip address <xxx.xxx.xxx.xxx>/24 to set an IP address for the BRI interface.

7.Enter frame-relayinterface-dlci<16-1007>to acquire Frame Relay DLCI Interface mode and assign a data-link connection identifier to the Frame Relay sub-interface.

8.Enter no shutdown to keep the BRI sub-interface enabled.

BRI Switched Line

1.Enter interface bri 0 to acquire Interface mode and select the BRI port.

2.Enter isdn switch-type<basic-5ess basic-dms100 basic-net3 basic-ni1 basic-ntt>to select the Central Office switch type for the ISDN port.

3.Enter isdn spid1 <SPID><LDR> for the SPID (ISDN service) and LDR (local directory) telephone numbers.

4.Enter isdn spid2 <SPID><LDR> for a second SPID as needed.

5.Enter no shutdown to keep the BRI interface enabled.

6.Enter dialer pool-member<1-255> priority <0-255>to add a dialer pool and associated priority to this BRI interface. You can add additional dial pools as needed.

7.Enter exit to quit BRI Interface mode.

8.Enter interface dialer <0-255>to acquire Interface mode and select the Dialer port.

9.Enter ip address <xxx.xxx.xxx.xxx/24 to set an IP address for the Dialer port.

10.Enter encapsulation ppp to select PPP encoding.

11.Enter dialer string <phone number> class <Map Class name> to specify the destination number and associated Map Class.

12.Enter any additional dialer strings as instructed above.

13.Enter dialer pool <1-255>to create a dial pool from which the dialer interface will select a physical interface.

14.Enter show interface to verify your ISDN and dialer configuration.

15.Enter no shutdown to keep the Dialer interface enabled.

Remember to save your configuration after all edits.