Page 13
Image 13
Back wall

Installation

CLEARANCES TO COMBUSTIBLES - FREESTANDING:

These dimensions are minimum clearances but it is recommended that you ensure sufficient room for serving, routine cleaning and maintenance.

 

Back wall

 

 

3" (76mm)

Adjacent

 

wall

 

 

2"

wall

 

(51mm)

 

 

Side

6"

 

 

(152mm)

 

Minimum

 

 

6" (150mm)

 

 

Figure 10: Meridian on Floor

 

Figure 11: Minimum Clearances to Combustibles for

Protection.

 

Freestanding Meridian.

This pellet stove requires floor protection. The floor protection must be non-combustible, extending beneath the stove the full width and depth of the unit including 6“ (150 mm) in front for ember protection.

ALCOVE CLEARANCES - FREESTANDING:

Minimum Width

36" (914mm)

Minimum Height

48" (1219mm)

Maximum Depth

30" (762mm)

Figure 12: Alcove Clearances Freestanding Meridian.

13

Page 13
Image 13
Enviro Meridian Installation, Back wall, 3 76mm, Adjacent, 51mm, 152mm, Side, 6 150mm, Minimum Width, 36 914mm

FAQ

What are the minimum clearances for the back wall and adjacent wall?

The minimum clearances for the back wall and adjacent wall are 3" (76mm) and 2" (51mm) respectively.

What kind of floor protection does the pellet stove require?

The pellet stove requires non-combustible floor protection, extending beneath the stove the full width and depth of the unit, including 6" (150mm) in front for ember protection.

What are the alcove clearances for the freestanding Meridian?

The minimum width is 36" (914mm), the minimum height is 48" (1219mm), and the maximum depth is 30" (762mm).