Enviro Meridian owner manual Outside Vertical Installation

Models: Meridian

1 44
Download 44 pages 7.41 Kb
Page 22
Image 22
Figure 28: Outside Vertical Installation.

Installation

OUTSIDE VERTICAL INSTALLATIONS - FREESTANDING:

To accomplish a outside vertical pipe installation, follow steps 1 through 5 in the “INSIDE VERTICAL INSTALLATIONS

-FREESTANDING” section and then finish it by performing the following (refer to Figure 28).

1.Install a tee with clean out on the outside of the house.

2.Install PL vent upward from the tee. Make sure that you install support brackets to keep the vent straight and secure.

3.Install ceiling thimble and secure the flashing as you go through the roof.

4.Ensure that the rain cap is approximately 24” (610 mm) above the roof.

Rain cap

Flashing

24"

(61 cm)

3" (7.5 cm)

Clearance

3"

(7.5cm)

Support

bracket

Tee with

cleanout

Type "L"

vent

Fresh air

intake

Figure 28: Outside Vertical Installation.

22

Page 22
Image 22