Enviro Meridian owner manual Installation, Lock fireplace damper in the open position

Models: Meridian

1 44
Download 44 pages 7.41 Kb
Page 23
Image 23
1.Lock fireplace damper in the open position.

Installation

HEARTH MOUNT INSTALLATION - FREESTANDING:

Clean-out

Fresh-air intake should com from chimney. If holes lready exist fresh-air intake can be taken through back of the fireplace or through the ash dump.

Damper Removed or Fastened Open

Mantel

Minimum 8" (20 cm) from top of stove

Min 6" (150 mm)

 

Floor

 

Protection

Masonry Fireplace

Combustible Floor

Manual background Rain cap

Storm collar

Figure 29: Hearth Mount - Side View.

1.Lock fireplace damper in the open position.

2.Install a positive flue connector at the fireplace dampers.

3.Connect a clean-out tee or a 90° elbow to the exhaust pipe.

4.Install flexible stainless steel liner or listed pellet vent to the top of the chimney.

Seal plate (cover plate)

Existing masonry flue

Vent pipe (single wall stainless flex pipe or solid PL vent)

Flexible vent connector (use this 5' [1520 mm] section Manual background of pipe to vent past fireplace damper or small shelf)

Manual background Fireplace damper location

Clean out tee

Existing fireplace

Figure 30: Hearth Mount - Over View.

23

Page 23
Image 23
Enviro Meridian owner manual Installation, Lock fireplace damper in the open position

FAQ

What is the minimum distance for the mantel from the top of the stove?

The minimum distance for the mantel from the top of the stove should be 8 inches (20 cm).

Where should the fresh air intake come from?

The fresh air intake should come from the chimney, and if holes already exist, it can be taken through the back of the fireplace or through the ash dump.

What should be done with the fireplace damper during installation?

The fireplace damper should be locked in the open position during installation.