TO SUPPLY POWER TO THE EXHAUST BLOWER:

Installation

NOTE:

Ensure that all vent connections are installed by placing three (3) screws evenly spaced and a small bead of high temperature silicone at each chimney connection. Also ensure that all vertical vent sections are properly supported and that all clearances to combustibles are maintained in accordance with the vent manufacturer’s specifications.

Siding

 

Vent termination cap

 

(stainless steel termination

90° elbow

hood) or 45° elbow with

 

rodent screen

 

Wall strap

Wall framing

 

(recommended with

 

use of vent pipe)

 

Vent pipe or 2 foot

 

(610 mm) riser

 

Pipe adapter (if

Wall thimble

using 2 foot riser)

 

Exterior blower

 

and housing

 

Horizontal frame

 

for thimble

 

Armour cable supplying

 

power to exterior blower

 

 

ENVIRO Meridian

Figure 32: Exhaust Blower Installation; Horizontal Termination.

TO SUPPLY POWER TO THE EXHAUST BLOWER:

Install an amour coated electrical cable from the exhaust blower housing, through the wall thimble, and attach to the pre-drilled hole in the left hand rear hopper pillar. Hook up to wires from the wiring harness for the exhaust blower. All electrical connections must be in accordance with local code requirements (see

WIRING DIAGRAM).

25

Page 25
Image 25
Enviro Meridian owner manual To Supply Power To The Exhaust Blower, Installation

FAQ

What are the key considerations for installing the Enviro Meridian indoor fireplace exhaust blower?

Key considerations include ensuring proper vent connections, maintaining clearances to combustibles, and proper electrical supply to the exhaust blower.

What type of vent termination cap is recommended for the installation?

A stainless steel termination cap is recommended for the vent termination.

What are the specifications for the recommended exhaust blower electrical supply?

An amour coated electrical cable should be installed from the exhaust blower housing, through the wall thimble, and attached to the pre-drilled hole in the left hand rear hopper pillar, then hooked up to the wires from the wiring harness for the exhaust blower.