Enviro Meridian A 45 elbow with a rodent screen may be used, steel termination hood, Installation

Models: Meridian

1 44
Download 44 pages 7.41 Kb
Page 20
Image 20
A 45° elbow with a rodent screen may be used

Installation

VERTICAL RISE WITH HORIZONTAL TERMINATION INSTALLATION (RECOMMENDED) - FREESTANDING:

A 45° elbow with a rodent screen may be used in place of the termination cap (or stainless steel termination hood).

Termination cap

 

90°elbow

 

Wall framing

 

Vertical section of vent pipe

 

Horizontal frame

Wall strap

 

for thimble

 

 

Clean

 

out tee

 

Wall

 

thimble

ENVIRO Meridian

 

Figure 25: Through Wall with Horizontal Termination.

THROUGH CONCRETE WALL WITH VERTICAL RISE INSTALLATIONS - FREESTANDING:

 

A 45° elbow with a rodent screen may be used

Horizontal frame

 

in place of the termination cap (or stainless

 

for thimble

Termination cap

steel termination hood).

Wall thimble

 

 

 

This is the recommended installation to use if

90°elbow

 

 

 

there is a concrete or retaining wall in line with

Wall framing

 

exhaust vent on pellet stove.

 

 

 

 

Vertical section

 

The termination must be 12 inches (30 cm)

of vent pipe

 

 

 

from the outside wall and 12 inches (30 cm)

 

 

above the ground.

 

 

 

 

Concrete Wall

 

������ ��������

Clean out tee

Figure 26: Vertical rise with Horizontal Termination.

20

Page 20
Image 20
Enviro Meridian A 45 elbow with a rodent screen may be used, in place of the termination cap or stainless, Installation

FAQ

What is the recommended installation for the Enviro Meridian indoor fireplace?

The recommended installation options include vertical rise with horizontal termination and through wall installation.

Can a 45 elbow with a rodent screen be used in place of the termination cap or stainless steel termination hood?

Yes, a 45 elbow with a rodent screen may be used in place of the termination cap or stainless steel termination hood.

How far must the termination be from the outside wall and above the ground?

The termination must be 12 inches (30 cm) from the outside wall and 12 inches (30 cm) above the ground.