Initial Installation

QUALIFIED INSTALLERS ONLY

8.Pull the control panel straight out (see Figure 52). There are two (2) tabs on the bottom of the control panel that fit in two (2) slots in the Sonnet cabinet bottom.

9.Slide the temperature sensor into the holding tabs below the left end of the burner behind the control panel.

10.Using a utility knife cut out the rectangle on the control panel between the two (2) fan symbols.

11.Make note of the order the connectors are in on the three (3) position switch and remove them. Slide the switch through the front of the hole that was just cut out and

reattach the connectors to the switch.

12.Re-install the control panel.

Figure 51: Grounding Power Cord.

Figure 52. Remove/Install Control Panel.

GAS LINE CONNECTION:

Warning: Only persons licensed to work with gas piping may

 

make the necessary gas connections to this appliance.

 

Gas Line Connection:

 

• A 3⁄8” NPT male pipe will have to be turned into the 3⁄8” NPT

 

female elbow at the lower right side rear of this fireplace (see

 

Figure 53). Consult the local authorities for local codes or use the

 

CAN/CGA B149 (1 or 2) installation code in Canada. In the US, gas

 

installations follow either local codes or the current edition of the

 

National Fuel Gas Code ANSI Z223.1.

 

• The efficiency of this unit is a product thermal efficiency rating

 

determined under continuous operating conditions and was

 

determined independently of any installed system.

Figure 53: 3⁄8” NPT female elbow.

• If the factory-built fireplace has no gas access hole(s) provided,

 

an access hole of 1.5 in (37.5mm) or less may be drilled through the lower sides or bottom of the firebox in a proper workmanship like manner. This access hole must be plugged with non-combustible insulation after the gas supply line has been installed.”

A shut-off valve is not supplied with this unit but one should be installed.

The appliance and its shut-off valves must be disconnected from the gas supply piping system during any pressure testing where the pressure exceeds 1⁄2 psig (3.45 KPa) or the valve will be damaged.

The unit must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at pressures equal to or less than 1⁄2 psig (3.45 KPa).