Enviro Sonnet, C-11089 owner manual Sheet metal screws evenly spaced

Models: C-11089 Sonnet

1 44
Download 44 pages 34.21 Kb
Page 20
Image 20

Initial Installation

QUALIFIED INSTALLERS ONLY

VENTING FIREPLACE INSERTS:

The ENVIRO Sonnet may be installed and vented into any solid fuel fireplace that has been installed in accordance with the National, Provincial/State and local building codes and has been constructed of non-combustible materials. Before starting, refer to INITIAL INSTALLATION - PREPARING YOUR SONNET FOR

INSTALLATION and INITIAL INSTALLATION - CONVERTING A DIRECT VENT FIREPLACE TO A B-VENT FIREPLACE. Please

reference the information in Table 5 and Figures 37, 38,and 41.

An approved chimney liner and rain cap must be used. A throat connector or flashing must be installed to ensure a tight seal, top performance, safety and efficiency. Carefully follow the manufacturer’s instructions that accompany the chimney liner kit. Use listed B-Vent or Flexmaster double walled aluminum flex vent.

If necessary, remove the vent collar plate from the top of the insert and connect it securely to the liner with sheet metal screws and/or hose clamps. Check for any tears in the liner at this point. IMPORTANT: The screws that hold the vent collar plate in its approved position must be installed.

Provide for proper and adequate venting and air supply for this appliance in accordance with the tables in the current National Fuel Gas Code, Z223.1/NFPA 54 or the CSA B149.1.

 

Table 5: Vent termination clearances

 

 

Minimum Clearance

Description

 

 

3 ft (0.9 m)

Clearance above the highest point where it passes through a roof surface, refer

to Figure 37.

 

24 in (0.6 m)

Clearance above a roof ridge, any other portion of a building, or any other ob-

struction within a horizontal distance of 10 feet (3 m), refer to Figure 37.

 

5 ft (1.5 m)

Clearance for a vent or chimney above either the highest connected appliance

drafthood outlet, or flue collar.

 

 

 

6 ft (1.83 m)

Clearance to mechanical air supply inlet.

 

 

3ft (0.9m)

Clearance to each side of center line extended above meter/regulator assembly.

 

 

6 ft (1.83 m)

Radial clearance around service regulator vent outlet.

 

 

12 in (30 cm)

Clearance above grade, verandah, porch, deck, or balcony.

 

 

 

Clearance to a building opening or combustion air inlet of another appliance,

3 ft (0.9 m)

except with the approval of the authority having jurisdiction for the following

 

reduced clearances.

9 in (0.23 m)

Exception for inputs up to and including 50,000 Btuh (15kW)

 

 

12 in (0.3 m)

Exception for inputs exceeding 50,000 Btuh (15kW) but not exceeding 100,000

Btuh (30kW)

 

 

 

NOTE: If the Sonnet unit is pulled out of its installation, and the vent air intake system is disconnected for any reason, ensure that the vent-air intake pipes are re-sealed with high-temperature sealant or silicone and reconnected with three

(3) sheet metal screws evenly spaced.

2ft (0.6m)

Roof ridge or

Minimum

3ft (0.9m)

any other portion

of a building

Minimum

Within

 

10ft (3m)

Figure 37: Roof Clearances.

20

Page 20
Image 20
Enviro Sonnet, C-11089 owner manual Sheet metal screws evenly spaced