Power Supply Unit Removal

Disassemble and Assemblv

StVlus Color Service Manual

3.2.2 Power Supply Unit (C137 PSB/PSE Board) Removal

1. Remove the uppercase. (See Section 3.2.l.)

2. Discomect the cables from comectors CN1 on the C137 PSB/PSEboard and CN5 on the C137

MAIN board.

3. Remove the 2 CBN (M3x8) screws securing the shield plate to the lower case via the C137

PSB/PSE board.

4. Remove the 3 CBB (N13x12) Screws securing the C137 PSB/PSE board to the lower case and

remove a CBN (0) (M3x6) screw fixing the earth line from the AC cable to the earth plate.

5. Push in the locking tab and take out the power supply unit by sliding it toward the back of the

printer.

c.

C137

C13

.

. c .

Figure 3-4. Power Supply Unit Removal

I

,

“L

3-4

Rev. A

Page 67
Image 67
Open full-size image