EPSON Stylus Color 600 Service Manual
Rev. A
3-
8
3.2.3 Control Panel Removal
1. Remove the upper housing (Refer to Section 3. 2.1)
2. Remove 2 screws (No.1) and remov e the control panel assembly f rom the printer mechanism and
disconnect the flat cable from t he connector of the panel assembly.
By removing the control panel assembly, the stacker assembly is also detached from t he pr int er
mechanism as it held by the control panel assembly.
WORK POINT
HOUSING, PANEL, LEFT
STACKER, ASSEMBLY
SHIELD PLATE, PANEL
C206 PNL Board
PANEL, ASSEMBLY
Figure 3-5. Control Panel Removal