Disassembly and Assembly Disassembly and Assembly of Panel Unit 45
4.3 Disassembly and Assembly of Panel Unit4.3.1 Panel Circuit Board Removal
1. Panel Unit Removal. (p41)
2. Remove one screw that secures the grounding plate.
3. Remove the grounding plate from the panel shield plate.
4. Remove six screws that secure the shield plate.
5. Remove the panel shield plate from the front middle cover.
6. Disconnect a harness from the panel circuit board.
7. Remove six hooks that secure the panel circuit board.
8. Remove the panel circuit board from the middle cover.
Figure 4-4. Panel Circuit Board Removal
C A U T IO N Do not touch the switch contacts on the panel circuit board with
bare hand; otherwise, contact error can occur.
C.B.P Tite 3x8,F/ZN
Tightening torque:0.6 ± 0.1 N
⋅
m
Front Middle Cover
Panel Circuit Board
Panel Shield Plate
C.B.P Tite 3x8,F/ZN
Tightening torque:0.6 ± 0.1 N
⋅
m
Grounding Plate