EPSON Stylus PHOTO RX600/610, RX620/630 Revision C
Disassembly and Assembly Disassembly and Assembly of Scanner Unit 47
4.4 Disassembly and Assembly of Scanner UnitFlowchart 4-2. Scanner Unit Disassembly Procedure
Panel Unit Removal (p.41)
Scanner Unit Removal (p.42)
HP Sensor Circuit Board (p49) CCD Module (p49)
Motor Assembly (p49)
START
Upper Housing Assembly Removal (p48)
C A U T IO N Perform disassembly and assembly for the scanner unit in an
environment free from dust. You are advised to work in a clean
room or on a clean bench, if possible.
Ensure that there are no stains or scratches on the document
table. Do not touch interior glass panel surface when installing
the scanner housing. Handle glass panel surface with care by
attaching protective sheet or paper.
Lubrication required. For lubrication, refer to the following
section.
6.3.2 Lubrication Points of the Scanner (p82)