EPSON Stylus PHOTO RX600/610, RX620/630 Revision C
Adjustment Adjustments by Adjustment Program 72
5.2.2.7 PW Adjustment
The PW sensor is installed on the bottom of the Carriage Unit (refer to p.16). Make
adjustment so that the program compensates for a dislocation of the Carriage Unit
resulting from its removal or replacement, and write the adjustment value in EEPROM.
Perform this adjustment in the order of printing the pattern checking adjustment
printing checking.
Media to be used : Normal paper (A4 Size)
Reference value : 5mm (top and bottom, and right and left)
Functions of buttons
[Print] : Prints the adjustment pattern.
[Input] : Select a desired adj ustm ent item and input the
adjustment value, and click the [Input] button to write
the adjustment value in EEPROM.
[Read] : You can check the current adjustment value.
Figure 5-11. PW Adjustment Screen
CHECK
P O I N T
For adjustment procedure, click the [How to adjust] button on
the adjustment program screen and see the display.
After writing the adjustment value in EEPROM, print the
pattern again and check the adjustment value for properness.