EPSON Stylus PHOTO RX600/610, RX620/630 Revision C
Disassembly and Assembly Disassembly and Assembly of Scanner Unit 49
4.4.2 CCD Module
1. Upper Housing Assembly Removal. (p48)
2. Remove a driven pulley from a timing belt by pressing the driven pulley Assembly
to loose tension of a timing belt.
3. Remove the CR shaft from lower housing.
4. Remove timing clamp, then remove timing belt from CC D module.
4.4.3 Motor Assembly
1. Upper Housing Assembly Removal. (p48)
2. Remove the CCD Module. (p.49)
3. Remove three screws that secure a grounding cable to the motor assembly.
4. Remove a grounding cable and the motor assembly from the scanner lower
housing.
4.4.4 HP Sensor Circuit Board
1. Upper Housing Assembly Removal. (p48)
2. Remove the Motor Assembly. (p.49)
3. Remove a screw that secures the HP sensor circuit board.
4. Remove the HP Sensor Circuit Board from lower housing.
Figure 4-8. Disassembly of Scanner Unit
C.B.P Tite 3x8,F/ZN
Tightening torque:0.7 ± 0.1 Nm
Timing Clamp
Grounding Cable
CCD Module Driven Pulley Assembly
Motor Assembly
HP Sensor Circuit Board
C.B.P Tite 3x8,F/ZN
Tightening torque:0.7 ± 0.1 Nm
CR shaft
Lower Housing
Timing Belt