EPSON Stylus PHOTO RX600/610, RX620/630 Revision C
Adjustment Adjustments by Adjustment Program 76
5.2.3.5 EEPROM data copyThe function is to back up → restore (to the new Main Board) the adjustment values
that have been stored in EEPROM on the Main Board. Use of this function will reduce
the man-hour for adjustment significantly.
The data to be backed up are as follows.
Note “* ”: For your confirmation, the adjustment values are displayed at “Adjusted items” in
the right area on the screen.
Figure 5-17. EEPROM Data Copy Screen
Table 5-2. Data to be Backed Up
Data to be Backed Up Page for
Adjustment
USB ID p68
Head ID p69
Head angular adjustment value p69
Bi-D adjustment value p71
PW sensor adjustment value p72
1st Dot Position Adjustment p70
Calorific Limitation Input p73
Ink consumption counters –
Waste ink pad counter p75
C A U T IO N After restoration, print the check patterns for all the adjustments
above and check each adjustment value. If there is any
abnormality, make adjustment for the relevant items.
Refer to “5.2.4 Check Pattern print (p77)”