Image 16
6. 5 TCP/IP menu

6. 5 TCP/IP menu

This menu can be opened by selecting Device, Configuration, and then the TCP/IP tab.

The TCP/IP menu helps you configure the TCP/IP settings on the network interface.

The following table explains in detail how this menu works.

Item

Explanation

 

 

Manual, Automatic,

Select the method for assigning an IP address. The choices here vary depending

DHCP, BOOTP, RARP

on the network interface.

 

If you select Automatic, a different IP address is assigned to the network

 

interface every time you turn on the device. If you do not have a DHCP server with

 

DNS support, select Manual here and specify an IP address directly.

 

If you select Automatic when DHCP, BOOTP, and RARP are all grayed out,

 

TMNet WinConfig will obtain an IP address from the server by automatically

 

determining the server type.

Set using Automatic

If this check box is selected, a private IP address is automatically assigned to the

Private IP Addressing

network interface by APIPA (Automatic Private IP Addressing) when there is no

(APIPA)

DHCP server on the network or there is no response from the DHCP server. The

 

private IP address will be in the range of 169.254.0.1 to 169.254.255.254.

 

This check box is grayed out if the IP Address Setting is set with Manual or

 

APIPA is not supported.

Set using PING

Select this check box when setting an IP address using the ARP/PING command.

 

 