Administrator’s Guide and Operating Instructions
!"Focus Camera – To define the camera that will respond to this Alarm Action. The default settings are Camera 1 for Alarm Action 1, Camera 2 for Alarm Action 2, and so on.
!"Enable – Check to enable the Alarm Output when the Alarm Action is triggered.
!"Alarm Out – To define which Alarm Output will be triggered when the Alarm Action is triggered. NC and NO signals are available, please refer to Alarm Out Setup. Click on the Down arrow button to select one of the Alarm Outputs (AO
!"Output – Alarm Out output state when the Alarm Action is triggered. For NC signal, it’s always open, for NO signal close. The Normal State above shows whether the selected Alarm Out is NC signal or NO signal.
!"Buzzer On – To activate the internal buzzer or not when the Alarm Action is triggered.
Note 1: When the Alarm Input that triggered the Alarm Action returns to normal, the internal buzzer and the corresponding Alarm Output will return to normal immediately.
Note 2: The processing power for the system is 25 FPS for PAL and 30 FPS for NTSC. So, if the total configured recording rate for all the cameras is 5 FPS, intensive recording means that the actual FPS for the
Fp = Fn x 25 / Ft for PAL, Fp = Fn x 30 / Ft for NTSC
Fp:
20