Installation and Operation, cont’d
L | |
| this 3.5 mm, |
| |
| page |
NThe
M | Audio output connector (DVI 201 A D Tx [Decora] only) — |
| Connect a stereo audio device to this 3.5 mm mini stereo jack to |
| receive the unbalanced audio output. Figure |
| shows how to wire the audio plug. |
Pin assignments and wiring
DVI connector pin assignments
Figure
18 C1 C2
9 |
|
| C4C5 |
17 | 24 | C3 |
Pin | Signal | Pin | Signal | Pin | Signal | |
1 | TMDS data 2– | 9 | TMDS data 1– | 17 | TMDS data 0– | |
|
|
|
|
|
| |
2 | TMDS data 2+ | 10 | TMDS data 1+ | 18 | TMDS data 0+ | |
|
|
|
|
|
| |
3 | TMDS data 2 | 11 | TMDS data 1 | 19 | TMDS data 0 | |
shield | shield | shield | ||||
|
|
| ||||
|
|
|
|
|
| |
4 | Spare | 12 | Spare | 20 | Spare | |
|
|
|
|
|
| |
5 | Spare | 13 | Spare | 21 | Spare | |
|
|
|
|
|
| |
6 | DDC clock | 14 | +5 V power | 22 | TMDS clock | |
Shield | ||||||
|
|
|
|
| ||
|
|
|
|
|
| |
7 | DDC data | 15 | Ground (+5 V) | 23 | TMDS clock+ | |
|
|
|
|
|
| |
8 | CEC control* | 16 | Hot Plug Detect | 24 | TMDS clock– | |
|
|
|
|
|
| |
C1 | Spare | C3 | Spare | C5 | Spare | |
|
|
|
|
|
| |
C2 | Spare | C4 | Spare |
|
| |
|
|
|
|
|
|
*CEC control on pin 8 is a proprietary usage, not the industry standard.
Figure 2-19 — DVI connectors
TP cable termination
N
CAT 6 cable must comply with the TIA/EIA T 568A or TIA/EIA T 568B wiring standard for all connections.
Figure
Side |
|
| Pins: |
|
|
|
|
| |||
| 1 2 3 4 5 6 78 |
|
|
|
|
|
|
| |||
|
|
|
| Connector |
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| TIA/EIA T | TIA/EIA T | Signal | ||
|
|
|
|
|
|
| 586 A | 586 B | |||
|
|
|
|
|
| Pin | Wire color | Wire color |
| ||
|
|
|
|
|
|
| |||||
|
|
|
|
|
| 1 | Data 0+ |
| CEC | ||
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 2 | Green | Orange | Data 0– |
| HPD |
|
|
|
|
|
|
| |||||
|
|
|
|
|
| 3 | ID Clock+ |
| |||
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
| TX | ||||
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 4 | Blue | Blue | Data 1+ |
| DDC Clk |
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 5 | Data 1– |
| +12 V | ||
|
|
| Insert |
|
|
|
|
|
| ||
|
|
| 6 | Orange | Green | ID Clock– |
| ||||
|
|
| Twisted |
| RX | ||||||
|
|
|
|
|
|
|
| ||||
| Pair Wires | 7 | Data 2+ |
| DDC data | ||||||
|
|
|
|
|
| 8 | Brown | Brown | Data 2– |
| Ground |
NTerminate both ends of both cables identically, in accordance with either the TIA/EIA T 568A or the TIA/EIA T 568B wiring standard.
Figure 2-20 — TP cable termination
NDo not use Extron’s
TP transmitter/receiver applications, but the
DVI 201 Tx/Rx will not work properly with this cable.
NIn order to fit in the junction box, the TP cables and
NIf necessary, test for proper cable connection (output 1 to input 1, output 2 to input 2) as follows:
1. Plug both TP cables into the powered unit.
2. Momentarily connect either of the cables on the opposite end into the unpowered unit‘s “2” connector.
If the unpowered unit’s Power LED is lit, the connection is correct.
If the unpowered unit’s Power LED is not lit,
unplug the connector on the unpowered end and connect the other cable to the “2” connector.
| DVI 201 Tx/Rx • Installation and Operation |