Equipment following the SCART interconnection standard may be connected using the RGBcS input cabling configuration.
4
Y | Y |
/VID | /VID |
C | C |
Composite video | |
input | input |
5SDI (serial digital interface) input connector — Connect an SDI signal to this female BNC connector.
Only DVS 406 D and DVS 406 AD models have an SDI connector.
6Output
Both outputs 6 and 7 are buffered and can be connected simultaneously to two different displays. The sync format will be the same for both outputs.
7Output BNC connectors — Connect coaxial cables from a display device to these BNCs for one RGBHV, RGBS, or RGsB/RsGsBs video output as follows:
R | G | B | H/HV | V | R | G | B | H/HV | V | R | G | B | H/HV | V |
|
| RGBHV |
|
| RGsB (Sync on Green) |
|
|
| RGBS |
|
| |||
|
|
|
|
| RsGsBs (output only if input is RsGsBs) |
|
|
|
|
|
Both outputs are buffered and can be connected simultaneously to two different displays. For RGB inputs, the output signal’s sync format is based on the format of the incoming RGB signal. For all other types of inputs, the user selects the output sync format. The sync format will be the same for both outputs.
8
The default protocol is 9600 baud, 1 stop bit, no parity, and no flow control.
The rear panel
Pin RS-232 function Description
1 | – | No connection |
2 | Tx | Transmit data |
3 | Rx | Receive data |
4 | – | No connection |
5 | Gnd | Signal ground |
6 | – | No connection |
7 | – | No connection |
8 | – | No connection |
|
|
|
9 | hardwired IR | IR input |
5 1
96
DB9 Pin Locations
Female