DVS 406 • Serial Communication
disable PAL film mode.
Example:
0 = off (default)
1 = on
enable enhanced mode.
Example:
0 = off (default)
1 = on
enable edge smoothing.
Example:
0 = off
1 = on (default)
enable the key effect.
Example:
setup
0 = off (default)
1 = on
Example:
(default) (RGB & sync output)
0 = off
1 = on (blue video & sync output only) blue & sync output for
and additional descriptions
0 = 0.0 seconds (default), 1 =
0.5 seconds, 2 = 1.0 seconds,
... in ½ second steps up to 10 = 5.0 seconds
Example: 3.5 second RGB delay
0 = cut,
1 = key,
2 = dissolve, 0.2 seconds,
3 = dissolve, 0.3 seconds,
... in 0.1 second steps up to 10 = dissolve, 1.0 seconds Example: 0.3 second dissolve
0 = RGBHV (default)
1 = RGBS
2 = RGsB (sync on green, SOG) Example: RGBHV sync output
0 = H-/V- (default)
1 = H-/V+
2 = H+/V-
3 = H+/V+
Example: H-/V+ sync polarity

The syntax for setting a special function is X? * X! # where X? is the function number and X! is the value. To view a function’s setting, use X? # where X? is the function number. In the following table the values of the X? variable are different for each command/function. These values are given in the rightmost column.

Command/response table for special function SIS commands

Command

ASCII Command Response

 

(host to scaler)

(scaler to host)

X!

values

Delay times

RGB delay (Triple-Action Switching)

3 *

X!

#RGB

X!

Example:

3*7#

RGB07

Input switch effects

Switching effect

4 *

X!

Example:4*3#

#Eff X!

Eff03

Scaler settings

Scaler output sync format

6 *

X!

Example:

6*1#

Scaler output polarity

7 *

 

X!

#Syn X!

Syn1

#Pol X!

Example:

7*1#

Pol1

Blue screen

Blue screen (blue & sync output only)

8*

X!

Example:

8*1#

#Blu X!

Blu1

Key effect

Key mode

9*

X!

Example:

9*1#

#Key X!

Key1

Edge smoothing

Edge enhancement

16*

X!

Example:

16*1#

#Fil X!

Fil1

Enhancement mode

Edge enhancement

12*

X!

Example:

12*1#

#Enh X!

Enh1

PAL film mode (2:2 pulldown detection)

PAL film mode detection

18*

X!

Example:18*0#

#Flm X!

Flm0

3-7

Page 41