Installation and Operation, cont’d
L | Output Audio — Plug an audio device into this pair, left and |
| right, of female RCA connectors (figure |
| stereo audio signal. |
Pin assignments and wiring
HDMI connector pin assignments
Figure
| 1 | 19 |
19 | 1 |
|
| 18 | HDMI | 2 |
| 2 HDMI 18 | |||
| Type A Receptacle |
| Type A Plug | |||||
|
|
|
|
|
|
|
| |
Pin | Signal |
| Pin | Signal |
| Pin | Signal | |
|
|
|
|
|
|
|
| |
1 | TMDS data 2+ |
| 7 | TMDS data 0– |
| 13 | CEC control* | |
|
|
|
|
|
|
|
| |
2 | TMDS data 2 |
| 8 | TMDS data 0 |
| 14 | Reserved | |
| shield |
|
| shield |
|
| (NC) | |
3 | TMDS data 2- |
| 9 | TMDS data 0- |
| 15 | SCL | |
|
|
|
|
|
|
|
| |
4 | TMDS data 1+ |
| 10 | TMDS clock+ |
| 16 | SDA | |
|
|
|
|
|
|
|
| |
5 | TMDS data 1 |
| 11 | TMDS clock |
| 17 | DDC / CEC | |
| shield |
|
| shield |
|
| Ground | |
6 | TMDS data 1- |
| 12 | TMDS clock- |
| 18 | +5 V power | |
|
|
|
|
|
|
| ||
* CEC control on pin 13 is a proprietary |
| 19 | Hot plug detect | |||||
usage, not the industry standard. |
|
|
| |||||
|
|
|
Figure 2-19 — HDMI connectors
TP cable termination
N
CAT 6 cable must comply with the TIA/EIA T 568A or TIA/EIA T 568B wiring standard for all connections.
Figure
Side |
|
| Pins: |
|
|
|
|
| |||
| 1 2 3 4 5 6 78 |
|
|
|
|
|
|
| |||
|
|
|
| Connector |
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| TIA/EIA T | TIA/EIA T | Signal | ||
|
|
|
|
|
|
| 586 A | 586 B | |||
|
|
|
|
|
| Pin | Wire color | Wire color |
| ||
|
|
|
|
|
|
| |||||
|
|
|
|
|
| 1 | Data 0+ |
| CEC | ||
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 2 | Green | Orange | Data 0– |
| HPD |
|
|
|
|
|
|
| |||||
|
|
|
|
|
| 3 | ID Clock+ |
| |||
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
| TX | ||||
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 4 | Blue | Blue | Data 1+ |
| DDC Clk |
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 5 | Data 1– |
| +12 V | ||
|
|
| Insert |
|
|
|
|
|
| ||
|
|
| 6 | Orange | Green | ID Clock– |
| ||||
|
|
| Twisted |
| RX | ||||||
|
|
|
|
|
|
|
| ||||
| Pair Wires | 7 | Data 2+ |
| DDC data | ||||||
|
|
|
|
|
| 8 | Brown | Brown | Data 2– |
| Ground |
|
|
|
|
|
|
|
|
|
|
|
|
NTerminate both ends of both cables identically, in accordance with either the TIA/EIA T 568A or the TIA/EIA T 568B wiring standard.
Figure 2-20 — TP cable termination
NDo not use Extron’s
TP transmitter/receiver applications, but the HDMI 201 Tx/Rx does not work properly with this cable.
NIn order to fit in the junction box, the TP cables and
NIf necessary, test for proper cable connection (output 1 to input 1, output 2 to input 2) as follows:
1. Plug both TP cables into the powered unit.
2. Momentarily connect either of the cables on the opposite end into the unpowered unit‘s “2” connector.
If the unpowered unit’s Power LED is lit, the connection is correct.
If the unpowered unit’s Power LED is not lit, unplug the connector on the unpowered end and connect the other cable to the “2” connector.
| HDMI 201 Tx/Rx • Installation and Operation |