Baud Rate and Protocol:

1200-57600 baud

9600 baud (default)

8 data bits

1 stop bit

no parity

Baud Rate Selection:

The IN1402 has a factory default baud rate of 9600 bps and can communicate at baud rates from 1200 up to 57,600. Baud rates can be specified by selecting Advanced Menu on the Main Menu.

The baud rate transmitted must match the baud rate selected on the IN1403.

Command Code Structure and Delimiters:

All commands sent to the unit must contain a leading code, the command code, and an ending code. Each command must be completely executed before the unit will accept a new command. When a command is completed, the unit provides a response code:

[OK] indicates that the command was received and executed.

[ERR] indicates that there is a problem with the code and the command was not executed.

The IN1403 can be set to recognize six sets of leading and end codes (delimiters). These are:

( ), [ ], { }, \ /, < >, and !#. The factory default serial delimiters are [ ]. The unit may be set to a different delimiter pair from the Advanced Menu (see page 14). The IN1403 will ignore all commands that do not contain the appropriate delimiters.

A complete command consists of

[

The leading code

CH4

The command code. In this case, CH4 would select Input 4.

]

The ending code

Sample command codes:

[CH1]

Select Input 1

[FRZ1]

Activate Freeze Frame

Serial Cable Connection:

When controlling only one IN1403 unit, connect the RS-232 cable as follows:

Controller Transmit

to

IN1403 Receive

Controller Ground

to

IN1403 Ground

Controller Receive

to

IN1403 Transmit

When controlling multiple IN1403 units, connect the RS-232 cable as follows:

Controller Transmit

to

Each IN1403 Receive

Controller Ground

to

Each IN1403 Ground

Controller Receive

to

Only one IN1403 Transmit

When controlling multiple units, the Controller Receiver Terminal and each IN1403 Transmit Terminal is left unconnected. Multiple IN1403 Transit Lines may not be connected together; otherwise signal contention from multiple units will result. Therefore, “receive” information is only available from one IN1403 in this configuration. Each unit must be set to different delimiters.