The syntax for setting a special function is X? * X! # where X? is the function number and X! is the

value. To view a function’s setting, use X? # where X? is the function number. In the following table the values of the X? variable are different for each command/function. These values are given in the rightmost column.

Command/response table for special function SIS commands

 

Command

ASCII Command Response

 

values

 

X!

 

 

(host to scaler)

(scaler to host)

and additional descriptions

 

PAL file mode (2:2 pulldown detction)

 

 

 

 

 

 

 

 

 

 

Set mode on

18*1#

PDn1

Set PAL file mode on.

 

Set mode off

18*0#

PDn0

Set PAL file mode off.

 

 

 

 

 

 

 

View file mode status

18#

PDn X2

Show PAL file mode status.

 

Blue mode

 

 

 

 

 

 

 

 

 

 

 

Set Blue mode on

8*1#

Blu1

Set Blue mode on.

 

Set Blue mode off

8*0#

Blu0

Set Blue mode off.

 

 

 

 

 

 

 

View Blue mode status

8#

Blu X2

Show Blue mode status.

Auto switch

Set Auto switch mode on

10*1#

Aut1

Set Auto switch mode off

10*0#

Aut0

View Auto switch mode status

10#

Aut X2

Set Auto switch mode on. Set Auto switch mode off.

Show Auto switch mode status.

H Format (sync output format)

Set to horizontal sync

15*1#

HFm0

Set H format to off/0

 

 

 

(horizontal sync, default).

Set to composite sync

15*0#

HFm1

Set H format to on/1

 

 

 

(composite sync).

 

 

 

 

View H Format status

15#

HFm X2

Show H format mode status.

 

 

 

 

IN1502 • Serial Communication

3-7

Page 35