IPL T S Series • Installation
2-6
PRELIMINARY
IPL T S Series • Installation and Operation
2-6
Installation and Operation, cont’d
COM1
LAN
POWER
12V
.5A MAX
COM5
TXRX TXRX
COM6
COM3
TXRX TXRX
COM4
COM2
00-05-A6-00-00-06
6
10
7
5
1 2 4
3
Figure 2-7 — IPL T S6 interface back panel
Power a Power connection — Plug the unit’s external 12 VDC power supply into this
connector. The power supply is provided with the unit.
C When you are connecting the power supply, voltage polarity is extremely
important. Applying power with incorrect voltage polarity could damage
the power supply and the interface. Identify the power cord negative lead by
the ridges on the side of the cord.
SECTION A–A
Ridges
Smooth
Power Supply
Output Cord
A A
3/16”
(5 mm) Max.
Ground
+12 VDC
External
Power Supply
(12 VDC, 1 A )
AC Power Cord
Orange Captive
Screw Connector
Power Supply
Output Cord
Figure 2-8 — Power connector wiring
N Do not tin the stripped power supply leads before installing the captive screw
connector. Tinned wires are not as secure in the captive screw connectors and
could pull out.
C The two power cord wires must be kept separate while the power supply is
plugged in. Remove power before continuing.
To verify the polarity before connection, plug in the power supply with no load and
check the output with a voltmeter.