IPL T S Series • Communication and Control 4-17

Command

ASCII (Telnet)

URL Encoded (Web)

Response

Additional description

 

(host to unit)

(host to unit)

(unit to host)

 

 

 

 

 

 

Erase current

E//EF}

W//EF

Ddl]

 

directory and

 

 

 

 

subdirectories 24 28

 

 

 

 

 

 

 

 

 

List files from current

EDF}

WDF

 

 

directory

 

 

 

 

Get connection listing

ECC }

WCC

[number of connections]]

 

 

 

 

or Icc [total number of client

 

 

 

 

connections]]

 

Example:

ECC }

WCC

002]

The example shows two client connections.

Stream files via Telnet or RS-232

NFile streaming commands should be used by advanced programmers only.

Load file to user flash E+UF filesize, filename}

{raw, unprocessed data in a file of Upl]

memory24, 28

up to filesize}

NIf the IPL T S unit has insufficient memory available to store the sent file, it responds with Fld ] (failed) instead of with Upl ].

 

 

____

 

 

response is followed by a Fwm ] (firmware mismatch) response.

 

 

 

 

Retrieve file from user

EfilenameSF}

1B filename 53 46 0D

{responds with 4 bytes of file

 

 

 

flash memory28

 

 

size,+ raw unprocessed data

 

 

 

 

 

 

in file}

 

 

 

Load files to user

Use a POST command on port 80 by the delimited data to be written to the flash file memory.

 

 

 

flash memory

 

 

 

 

 

 

Retrieve file from user

Send a page GET on port 80 followed by: WSF

{responds with raw

 

 

 

flash memory

 

 

unprocessed data in file}

 

 

 

Example:

http://192.168.254.254/mypage.html?cmd=WSF

{data from the file mypage.html.}

 

 

 

 

 

 

 

 

 

Reset (zap)/erase commands

 

 

 

 

 

Erase all files from

E ZFFF}

W ZFFFpf]

Zpf]

 

 

 

flash memory24

 

 

 

 

 

 

Reset all device

E ZXXX}

W ZXXX

Zpx]

The “reset all settings” command does not

settings to factory

 

 

 

affect IP settings or flash memory.

 

 

defaults24

NThis is a product-dependent reset: flex I/O defaults back to TTL input, contact closure defaults to open, relays are reset to open, current sensing thresholds are reset to default, receive time-outs are reset back to defaults, port redirects are terminated. Consult product-specific documentation for settings affected and default values. Excludes IP settings such as IP address, subnet mask, gateway IP address, and IP security-level table, and does not remove the file system.

Absolute system reset, E ZY}

W ZY

Zpy]

but retain IP24

 

 

NThis command is intermediate between the ZXXX and ZQQQ commands. It is an absolute system reset excluding IP settings (IP address, subnet mask, gateway IP address, unit name, DHCP settings, port mapping). This allows you to maintain communication with the device. This reset is recommended after a firmware update. It erases the file system.

N

Firmware can be updated by using this command to upload an

.

s19 file to the

IPL T S

device

.

If the

IPL T S unit determines that the file is not intended for its model, the Upl

]

Page 57
Image 57
Extron electronic IPL T S Series manual Stream files via Telnet or RS-232

IPL T S Series specifications

The Extron IPL T SFI244 is a sophisticated control system that is designed to streamline the management and operation of audiovisual equipment in a variety of environments, including conference rooms, classrooms, and auditoriums. This model falls under the IPL T S Series, renowned for its superior performance and user-friendly interface, making it a popular choice for integrators and users alike.

One of the standout features of the IPL T SFI244 is its advanced interface. It boasts an intuitive touch panel that enables users to manage multiple devices from a single control point, significantly simplifying the AV experience. The system supports a wide range of functions, including source selection, volume control, and the management of lighting and screen mechanisms. This centralized control helps to enhance collaboration and communication, particularly in educational and corporate settings.

The IPL T SFI244 integrates seamlessly with a variety of Extron technologies, including the GlobalViewer Enterprise, providing real-time monitoring and management capabilities. This web-based software solution gives administrators the ability to control AV systems remotely, ensuring optimal performance and minimizing downtime.

Another key characteristic of the IPL T SFI244 is its versatility. It incorporates various input and output options, such as HDMI, VGA, and audio connections, to accommodate different audiovisual equipment. This flexibility allows for easy integration into existing setups, catering to diverse applications and user preferences.

In terms of design, the IPL T SFI244 is engineered with reliability and durability in mind. It is equipped with features that enhance its performance in professional environments, including programmable button layouts that can be customized by users. This personalization ensures that the control system meets specific operational requirements, further enhancing the user experience.

Furthermore, the IPL T SFI244 is built with energy efficiency in mind, utilizing technologies that reduce power consumption without compromising performance. This eco-friendly approach not only supports sustainability initiatives but also contributes to long-term cost savings for organizations.

In summary, the Extron IPL T SFI244 is a comprehensive control solution that combines advanced technology, user-friendly features, and robust performance. Its ability to integrate with various AV equipment, coupled with its customizable interface and reliability, makes it an excellent choice for a wide range of applications, paving the way for more efficient and effective audiovisual management.