Extron electronic IPL T S Series X2%, X2, X2&, X2 ,  X!*X2CY, CpnX!CtyX2,  X!*X3,X3!CF, X3, X3

Models: IPL T S Series

1 79
Download 79 pages 22.12 Kb
Page 47
Image 47

IPL T S Series • Communication and Control 4-7

Command

ASCII (Telnet)

URL Encoded (Web)

Response

 

Additional description

 

(host to unit)

(host to unit)

(unit to host)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Configure

E X!* X2%, X2^, X2&, X2*CP}

WX! %2A X2% %2CX2^ %2CX2&

Cpn X!•CcpX2%, X2^, X2&,

 

Set baud rate (X2%), parity (X2^), data bits

parameters24

 

%2CX2*CP 

X2*]

(X2&), and stop bits (X2*) for port X!.

 

 

 

 

 

X2% = 300, 600, 1200, 1800, 2400, 3600, 4800,

 

 

 

 

7200, 9600, 14400, 19200, 28800, 38400, 57600,

 

 

 

 

or 115200 baud.

 

 

 

 

 

 

X2^ = parity (only the first letter is needed):

 

 

 

 

 

Odd

 

 

 

 

 

 

E

 

ven

 

 

 

 

 

 

None (default)

 

 

 

 

 

 

M

 

ark

 

 

 

 

 

 

S

 

pace.

 

 

 

 

 

 

X2& = data bits: 7, 8

(default = 8).

 

 

 

 

 

X2* = stop bits: 1, 2

(default = 1).

Example:

E4*9600,N,8,1CP}

W4%2A9600%2CN%2C8%2C

Cpn4•Ccp9600,N,8,1]

 

Set the projector control port for 9600 baud,

 

 

1CP

 

 

no parity, 8 data bits, and 1 stop bit.

View parameters

E X!CP}

W X!CP

X2%, X2^, X2&, X2(]

 

 

 

 

 

 

Configure mode24

E X!*X2(CY}

WX!%2AX2(CY

CpnX!•CtyX2)]

 

 

 

 

 

 

View mode

E X!CY}

WX!CY

X2(]

 

 

 

 

 

 

Configure flow

E X!*X3),X3!CF}

WX!%2AX3)%2CX3!CF

CpnX!•CflX3), X3!]

 

 

 

 

 

 

control

 

 

 

 

 

 

 

 

 

View flow control

E X!CF}

WX!CF

X3), X3!]

 

 

 

 

 

 

Configure receive

E X!*X1&*X2)*X2#*X2!CE}

WX!%2AX1&%2AX2)%2AX2#

CpnX!•CceX1& , X2) , X2# , 

 

Set the time to wait (X1& = waiting time in

timeout24

 

%2AX2!CE

X2!]

tens of ms until receipt of the first response

 

 

 

 

character before terminating the receive

 

 

 

 

operation, X2) = waiting time in

 

 

 

 

 

tens of ms between characters before

 

 

 

 

 

terminating) and priority status

 

 

 

 

 

(X2#: 0 = default, use send data string

 

 

 

 

 

command parameters; 1 = use configure

 

 

 

 

 

receive timeout command parameters) for

 

 

 

 

 

port X!. X2! = #L or #D (see previous page).

 

 

 

 

 

The response includes leading zeros.

View receive timeout

E X!CE}

WX!CE

X1& , X2) , X2# , X2!]

 

 

 

 

 

 

Configure pass-thru

E X!*X5)*X5#*X2!CD}

WX!%2AX5)%2AX5#%2AX2!

CpnX!•CcdX5),X5#,X2!]

 

 

 

 

 

 

mode24

 

CD

 

 

 

 

 

 

 

Terminate pass-thru

E X!*0CD}

WX!%2A0CD

CpnX!•Ccd

 

 

 

 

 

 

mode24

 

 

00000,00000,00000L]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 47
Image 47
Extron electronic IPL T S Series manual X2%, X2, X2&, X2 ,  X!*X2CY, CpnX!CtyX2,  X!*X3,X3!CF, CpnX!CflX3, X3,  X!*0CD