Extron electronic IPL T S Series manual X5,X5#,X2, X6 TC, Series Communication and Control

Models: IPL T S Series

1 79
Download 79 pages 22.12 Kb
Page 48
Image 48

4-8 IPL T

Command

ASCII (Telnet)

URL Encoded (Web)

Response

Additional description

 

(host to unit)

(host to unit)

(unit to host)

 

View pass-thru

E X!CD}

WX!CD

X5),X5#,X2!]

mode24

 

 

 

S Series • Communication and Control

Ethernet data port

Set current connection E0*X6(TC} port timeout

View current

E0TC}

connection port

 

timeout

 

Set global IP port

E1*X6(TC}

timeout

 

View global IP port

E1TC}

timeout

 

W0%2AX6(TC

Pti0*X6(]

The current port timeout period applies

 

 

to the currently open Telnet session only.

 

 

When you start another Telnet session, it

 

 

uses the default global port timeout period.

 

 

X6( = timeout period in seconds. See

 

 

the description above. This variable is

 

 

applicable only when the IPL T S unit is

 

 

connected via Ethernet. If the IPL T S device

 

 

is connected via RS-232 protocol, only the

 

 

global timeout commands apply, and any

 

 

commands involving X6( return the E13

 

 

error response.

W0TC

X6(]

 

W1%2A X6(TC

Pti1*X6(]

The global port timeout is the default

 

 

timeout period for all Telnet sessions.

 

 

X6( = IP connection timeout period

 

 

in seconds. Each step is specified

 

 

in 10-second intervals (1 - 65000,

 

 

default = 30 = 300 seconds). If no data is

 

 

received during the specified period, the

 

 

Ethernet connection closes. Responses are

 

 

returned with leading zeros.

 

 

This timeout period is applicable only

 

 

when the IPL T S unit is connected via

 

 

Ethernet, and you must be logged in as an

 

 

administrator to change this setting.

W1TC

X6(]

 

Communication and Control, cont’d

Page 48
Image 48
Extron electronic IPL T S Series manual X5,X5#,X2, X6 TC, Series Communication and Control, Ethernet data port