Communication and Control, cont’d

Server Side Include Using a Remote SIS command

 

 

 

SIS Command

 

 

<!--#echo var=" W 1

* 50 *

3 *

3L RS

 

Hello "-->

 

 

Delimiter

Port

Time to

Time

Length or Command

Delimiter

 

 

Data to be

 

Number

wait for

between

Delimiter

 

passed to

 

 

first character

characters

parameter

 

external device

 

 

of response

in response

 

 

via a serial port

SIS Command

Elements

*Type with no spaces.

Figure 4-2 — Example of an SSI “remote” command

In the example above, a “remote” serial command sends the word “Hello” and waits up to 50 ms for a response (until three characters are received). For more information on this command, refer to the “Command/response table for Simple Instruction Set (SIS) commands”, earlier in this chapter.

Query string

A query string is the portion of a URL that appears after the question mark. The query string contains parameters or instructions for the Web server to execute.

The basic format for a query string within a link is:

<a href=”index.html?cmd=x”>Input #1</a>

Where x is the SIS command to be executed.

When a link is accessed on a Web page, the URL is passed to the Web server to tell it which Web page to return to the browser. The portion of the URL after the question mark is the query string, which contains the SIS command that the IPL T S interface removes and executes.

As with SSI formatted commands, query strings can use any valid SIS command— either “host” or “remote”.

The query string in the figure below turns off DHCP on the IP Link device.

URL with a Query String using a Host SIS command

 

 

 

 

SIS Command

 

 

 

<a href="index.html

?

cmd=

W0DH

">

DHCP off </a>

HTML code

Starts

Tells Web server

SIS command

HTML code

Linked Text

Closes

Query String

for a link

 

 

an SIS command

to be processed

for a link

 

Link

 

 

 

follows

by the IP Link

 

 

 

 

 

 

 

 

 

*Type with no spaces.

Figure 4-3 — Example of a host query string command

URL with a Query String using a Remote SIS command

SIS Command

<a href="index.html ? cmd=

W 2 RS

1!

"> Input #1 </a>

HTML code

for a link

Starts

Tells Web

Delimiter

Port Command

Delimiter Data to

Query String

 

 

server an

 

Number

be passed to

SIS command

external device

follows

via a serial port

 

HTML

Linked

Closes

code

Text

Link

for a link

 

 

*Type with no spaces.

Figure 4-4 — Example of a remote query string command

In the figure above, the data string that follows the pipe () symbol is sent to the attached controlled device on serial port #2. This string instructs an attached Extron switcher to change to input #1.

4-20 IPL T S Series • Communication and Control

Page 60
Image 60
Extron electronic IPL T S Series manual Query string, Href=index.html?cmd=xInput #1/a

IPL T S Series specifications

The Extron IPL T SFI244 is a sophisticated control system that is designed to streamline the management and operation of audiovisual equipment in a variety of environments, including conference rooms, classrooms, and auditoriums. This model falls under the IPL T S Series, renowned for its superior performance and user-friendly interface, making it a popular choice for integrators and users alike.

One of the standout features of the IPL T SFI244 is its advanced interface. It boasts an intuitive touch panel that enables users to manage multiple devices from a single control point, significantly simplifying the AV experience. The system supports a wide range of functions, including source selection, volume control, and the management of lighting and screen mechanisms. This centralized control helps to enhance collaboration and communication, particularly in educational and corporate settings.

The IPL T SFI244 integrates seamlessly with a variety of Extron technologies, including the GlobalViewer Enterprise, providing real-time monitoring and management capabilities. This web-based software solution gives administrators the ability to control AV systems remotely, ensuring optimal performance and minimizing downtime.

Another key characteristic of the IPL T SFI244 is its versatility. It incorporates various input and output options, such as HDMI, VGA, and audio connections, to accommodate different audiovisual equipment. This flexibility allows for easy integration into existing setups, catering to diverse applications and user preferences.

In terms of design, the IPL T SFI244 is engineered with reliability and durability in mind. It is equipped with features that enhance its performance in professional environments, including programmable button layouts that can be customized by users. This personalization ensures that the control system meets specific operational requirements, further enhancing the user experience.

Furthermore, the IPL T SFI244 is built with energy efficiency in mind, utilizing technologies that reduce power consumption without compromising performance. This eco-friendly approach not only supports sustainability initiatives but also contributes to long-term cost savings for organizations.

In summary, the Extron IPL T SFI244 is a comprehensive control solution that combines advanced technology, user-friendly features, and robust performance. Its ability to integrate with various AV equipment, coupled with its customizable interface and reliability, makes it an excellent choice for a wide range of applications, paving the way for more efficient and effective audiovisual management.