Extron electronic IPL T S Series manual Symbol definitions

Models: IPL T S Series

1 79
Download 79 pages 22.12 Kb
Page 43
Image 43

Symbol definitions

] = CR/LF (carriage return/line feed)

}= Carriage return (no line feed)

= Space character

X! = Specific port number (01-99)

The port number is represented as two ASCII characters (2 bytes). For example, port 05 would be represented as 30 35 in hex.

X@ = Command data section

X@ is the command string for sending data to an A/V product (e.g., a switcher or projector) attached to an IPL T S unit. For remote processing examples, see “Customization” later in this chapter.

NSee "URL Encoding” for command restrictions.

X# = Greenwich Mean Time (GMT) offset value (-12.0 to +14.0) X% = On/Off status: 0 = Off/Disable; 1 = On/Enable

X1! = Unit version number

X1@ = Name is a text string up to 24 characters drawn from the alphabet (A-Z), digits (0-9), minus sign/

hyphen (-). No blank or space characters are permitted as part of a name. No distinction is made between upper and lower case. The first character must be an alpha character. The last character must not be a minus sign/hyphen.

X1# = Set local date and time format (MM/DD/YY-HH:MM:SS) (e.g., 02/01/06-10:54:00)

Read local date and time format (day of week, date month year HH:MM:SS) (e.g., Tues, 14 Feb 2006 18:19:33)

X1$ = IP address (xxx.xxx.xxx.xxx). Leading zeros in each of four fields are optional in setting values,

and are suppressed in returned values.

X1% = Domain name (e.g., extron.com, icia.org)

X1& = Time in tens of milliseconds to wait for characters coming into a serial port before terminating

(default=1=10 ms, max.=32767)

X1* = Hardware (MAC) address (xx-xx-xx-xx-xx-xx)

X1( = Subnet mask (xxx.xxx.xxx.xxx). Leading zeros in each of four fields are optional in setting

values, and are suppressed in returned values.

X2) = Time in tens of milliseconds to wait between characters coming into a serial port before terminating

(default=2=20 ms, max.=32767)

X2! = Parameter to set either Length of message to receive or Delimiter value. If length delimited, use xxL, where xx is the length of the incoming message in bytes. If character delimited, use xxD, where xx is the decimal ASCII value of the delimiting character.

X2@ = Verbose/response Mode: 0=clear/none; 1=verbose mode; 2=tagged responses for queries; 3=verbose mode and tagged responses for queries. (Default = 0 for Telnet connections, 1

for RS-232 host control).

NIf tagged responses is enabled, all read commands return the constant string + the data, as setting the value does. For example, Command: Esc CN }

Response: Ipn • X1@ }

X2# = Priority status for receive timeout:

0 = priority set to Send Data String command parameters;

1 = priority set to Configure Receive Timeout command parameters.

X2% = Baud rate: 300, 600, 1200, 1800, 2400, 3600, 4800, 7200, 9600, 14400, 19200, 28800, 38400, 57600, 115200

X2^ = Parity: Odd, Even, None, Mark, Space (only the first letter is required)

X2& = Data bits: 7, 8

X2* = Stop bits: 1, 2

X2( = Port type: 0 = RS-232; 1 = RS-422; 2 = RS-485

X3) = Flow control: Hardware, Software, None (only the first letter is needed)

X3! = Data pacing (specified in milliseconds between bytes): 0–1000 (default = 0 ms)

X3# = Password: allows a maximum length of 12 alpha numeric characters. Special characters are not allowed.

NUser password cannot be assigned if no administrator password exists and returns E14. If an admin password is cleared, then the user password is removed too.

IPL T S Series • Communication and Control

4-3

Page 43
Image 43
Extron electronic IPL T S Series manual Symbol definitions, X1% = Domain name e.g., extron.com, icia.org

IPL T S Series specifications

The Extron IPL T SFI244 is a sophisticated control system that is designed to streamline the management and operation of audiovisual equipment in a variety of environments, including conference rooms, classrooms, and auditoriums. This model falls under the IPL T S Series, renowned for its superior performance and user-friendly interface, making it a popular choice for integrators and users alike.

One of the standout features of the IPL T SFI244 is its advanced interface. It boasts an intuitive touch panel that enables users to manage multiple devices from a single control point, significantly simplifying the AV experience. The system supports a wide range of functions, including source selection, volume control, and the management of lighting and screen mechanisms. This centralized control helps to enhance collaboration and communication, particularly in educational and corporate settings.

The IPL T SFI244 integrates seamlessly with a variety of Extron technologies, including the GlobalViewer Enterprise, providing real-time monitoring and management capabilities. This web-based software solution gives administrators the ability to control AV systems remotely, ensuring optimal performance and minimizing downtime.

Another key characteristic of the IPL T SFI244 is its versatility. It incorporates various input and output options, such as HDMI, VGA, and audio connections, to accommodate different audiovisual equipment. This flexibility allows for easy integration into existing setups, catering to diverse applications and user preferences.

In terms of design, the IPL T SFI244 is engineered with reliability and durability in mind. It is equipped with features that enhance its performance in professional environments, including programmable button layouts that can be customized by users. This personalization ensures that the control system meets specific operational requirements, further enhancing the user experience.

Furthermore, the IPL T SFI244 is built with energy efficiency in mind, utilizing technologies that reduce power consumption without compromising performance. This eco-friendly approach not only supports sustainability initiatives but also contributes to long-term cost savings for organizations.

In summary, the Extron IPL T SFI244 is a comprehensive control solution that combines advanced technology, user-friendly features, and robust performance. Its ability to integrate with various AV equipment, coupled with its customizable interface and reliability, makes it an excellent choice for a wide range of applications, paving the way for more efficient and effective audiovisual management.