Extron electronic IPL T S Series manual IP address is reset to, Subnet mask is reset to

Models: IPL T S Series

1 79
Download 79 pages 22.12 Kb
Page 58
Image 58

4-18 IPL T S Series • Communication and Control

Command

ASCII (Telnet)

URL Encoded (Web)

Response

Additional description

 

(host to unit)

(host to unit)

(unit to host)

 

 

 

 

 

 

Absolute system

E ZQQQ}

W ZQQQ

Zpq]

This resets all device settings/memories

reset24

 

 

 

to factory default; however, the firmware

 

 

 

 

version remains the same. This includes all

 

 

 

 

settings, adjustments, PINs, the IP address,

 

 

 

 

and subnet mask. Files in flash memory are

 

 

 

 

also erased by this command.

 

 

 

 

The IP address is reset to 192.168.254.254,

 

 

 

 

the subnet mask is reset to 255.255.0.0.

 

 

 

 

This command is identical to reset mode 5,

 

 

 

 

discussed in “Resetting the Unit” in

 

 

 

 

chapter 2.

 

 

 

 

 

NUnlike various PC operating systems, a file and directory on the Extron product are allowed to have the same name.

Communication and Control, cont’d

Page 58
Image 58
Extron electronic IPL T S Series manual IP address is reset to, Subnet mask is reset to, Discussed in Resetting the Unit