Connection and Configuration, cont’d

Figure 3-12 — System Settings screen

Port Settings

The Port Settings page grants access to view or change the Serial Port Settings:

Serial port number — use a radio button to select the desired port

Port type — RS-232 (default), RS-422, 4S-485

Baud rate — 300, 600, 1200, 1800, 2400, 3600, 4800, 7200, 9600 (default), 14400, 19200, 28800, 38400, 57600, 115200

Parity — 7, 8 (default)

Stop bits — 1 (default), 2

Flow control — None (default), Hardware, Software

Serial Bridging — On, Off (default)

Remote IP Address — view the remote IP address

Remote TCP Port — view the remote TCP port

Figure 3-13 — Port Settings screen