Programmer’s Guide, cont’d

Command/response table for IP SIS commands

Command

ASCII Command

Response

Additional description

 

(host to switcher)

(switcher to host)

 

Set ISM name (location)

 

 

 

CN

Ipn•

 

 

 

 

Esc

 

X30

X30

 

 

 

 

 

 

 

 

 

 

 

 

 

Read ISM name (location)

Esc

CN

X30

 

 

 

 

Set GMT/date

 

 

 

CT

Ipt•

 

 

 

Esc

 

X31

X32

 

The date and time entered should be Greenwich Mean Time (GMT).

Read GMT/date

Set IP address

Esc

CT

X32

 

 

 

 

 

 

 

 

 

 

 

 

CI

Ipi•

 

The switcher sends the response,

Esc

X33

X33

 

 

 

 

 

 

 

but the host may not receive it.

Read IP address

Read hardware address

Read # of open connections

Set administrator password

Read administrator password

Set user password

Read user password

Esc CI

X33

Esc CH

X35

Esc CC

X36

EscX34 CA

Ipa X34

Esc CA

X34

EscX34 CU

Ipu X34

Esc CU

X34

When the computer is connected to the switcher via the RS-232 link, the Admin and User password fields are not masked. If a password has been inadvertently changed to an unknown value, you can look up and, if desired, change a password in this window without knowing the current password.

Command/response table for special function SIS commands

The syntax for setting a special function is Xn * X? # where Xn is the value or variable (such as 35 in the first example below), X? is the function number (such as “set RGB delay” in the first example below), and # is the execute command. To view a function’s setting, use X? # where X? is the function number.

Command

ASCII Command

Response

Additional description

 

(host to switcher)

(switcher to host)

 

 

 

 

 

Delay times

 

 

 

RGB delay (Triple-Action Switching)

X2 * X20 *3#

X2

Dly

X20

Switching delay of the selected

 

 

 

input to the selected output.

 

 

 

Adjustable in 0.01 second steps

 

 

 

up to 50 = 5.0 seconds. 0 = 0.0

 

 

 

seconds (default), 1 = 0.1

 

 

 

seconds, 2 = 0.2 seconds, and so

 

 

 

on.

Example:

1*35*3#

1Dly35

RGB delay for output 1 set to 3.5

 

 

 

seconds.

Read RGB delay

X2 *3#

X20

Scaler settings

Output sync format

X2

*

X7

*6#

Syn

X7

0 = RGBHV (default).

 

 

 

 

 

 

1 = RGBS.

Example:

2*0*6#

 

Syn00

RGBHV signal on output 2.

Read output sync format

 

 

*6#

 

 

 

 

 

 

 

 

 

 

 

 

X2

 

X7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output polarity

 

X2

*

X8

*7#

Pol

X8

 

 

X8

:Horizontal/Vertical polarity

 

 

 

 

 

 

 

 

 

 

 

0

= H–/V–

2

= H+/V–

 

 

 

 

 

 

 

 

 

 

 

1

= H–/V+

3

= H+/V+

Example:

1*1*7#

 

Pol01

H–/V+ polarity on output 1.

Read output sync polarity

 

 

*7#

 

 

 

 

 

 

 

 

 

X2

 

 

X8

 

 

 

 

 

 

4-14 Integration Scaling Matrix Switcher • Programmer’s Guide

Page 58
Image 58
Extron electronic ISM 182 manual Command/response table for special function SIS commands, Delay times, Scaler settings