Figure 24. Identify Mode
Check the Identify checkbox, then click the update button. The device name will
appear on the local display. See the following example.
Figure 25. Identify Mode Example
NOTES: • The name will only display if a valid source is connected and has been
correctly detected by the VNC 200.
•The name only displays on the local display output. It does not appear as
part of the streamed source.
Device mode
A VNC 200 encoder can be configured in four modes:
• Enable Allows the source to be streamed.
• Disable Prevents a source from being streamed.
• Standby Prevents a source from being streamed.
• Test Displays a splash screen with the text “test mode”. Normal streaming is
suspended.
For normal operation, enable must be selected.
Audio statusWhere a valid digital audio signal is connected to the digital audio IN connector, the
type of signal will appear in the Audio Status field on the Configure (audioPort)
page.
The VNC 200 supports the auto-detection of 44100 Hz and 48000 Hz digital audio
sources.
VN-Matrix 200 Series • System Configuration 32