CHAPTER 3

OPERATION

UPS FRONT PANEL INDICATOR AND FUNCTION KEYS

1

2

3

4

5

 

6

 

7

 

 

 

 

 

1.LOAD LEVEL INDICATOR LEDs

9

10

8

11

*The first or bottom LED is lit when the output load is greater than 25% of the ` rated output of the UPS.

*The second LED is lit when the output load is greater than 50% of the rated output of the UPS.

*The third LED is lit when the output load is greater than 75% of the rated output of the UPS.

2.BATTERY LEVEL INDICATOR LEDs

*The third or top LED is lit when the battery is fully charged.

*The second LED is lit when the battery level is above the low battery warning level.led

*The first LED is lit when the battery level is above the battery cutoff voltage.

3.LINE / SITE WIRING FAULT INDICATOR LED

For models configured for standard 120 volt domestic usage, this LED is lit to a steady “on” state when Utility voltage is present. However, should the led flash on and off, it is an indication that the HOT and NEUTRAL wires are reversed some where in the building wiring. (Typically at the wall outlet.)

4.BATTERY MODE INDICATOR LED

This LED is lit when the unit is operating from battery.

17

Page 19
Image 19