VIEW OF OUTPUT VOLTAGE & GREEN MODE SELECT SWITCHES
(LOCATED ON THE UPS REAR PANEL)
OFF = 0
Disregard
“ON” Designation
DIP
SWITCHES
ON = 1 |
| SELECTION |
|
| TABLE |
|
| |
|
|
|
SWITCH SETTINGS FOR ALL MODELS
SW2 | SW1 |
| OUTPUT VOLTAGE 1 | OUTPUT VOLTAGE 2 | |||
|
|
|
|
| (All models) | ||
Down | Down |
|
| 208 Vac | 115 Vac | ||
Down | Up |
|
| 220 Vac (default) | 120 Vac | ||
Up | Down |
|
| 230 Vac | 125 Vac | ||
Up | Up |
|
| 240 Vac | 130 Vac | ||
| GREEN MODE SWITCH SETTINGS FOR ALL MODELS | ||||||
|
|
|
|
|
|
| |
|
| SW3 |
| FUNCTION |
|
| |
|
| Down |
| GREEN MODE ON |
|
| |
|
| Up |
| GREEN MODE OFF |
|
|