Changing the tool.

The application tool can be fastened offset at convenient working positions at 45° steps (or at 30° steps for the triangle-shaped sanding pad).

MULTIMASTER FMM 250 Q (Figure 3).

WARNING Beforemountingorreplacing application tools or accesso-

ries, pull the power plug. This preventive

safety measure rules out the danger of inju- ries through accidental starting of the power tool.

 

For all work or when chang-

CAUTION

 

ing application tools, always

wear protective gloves. Danger of injury from the sharp edges of the application tools. Application tools can become very hot while working. Danger of burns!

Loosen the quick-clamping lever and swivel it to the stop.

Pull out the fastening element.

Clean the tool holder, the applica- tion tool and the fastening element.

Place the application tool exactly onto the star-shaped tool holder. Pay attention that the application tool has a flush fit.

Insert the fastening element to the stop into the tool holder.

Swivel the quick-clamping lever back until it engages.

 

Protect your hand and fin-

CAUTION

 

gers from being bruised/

crushed from the snapping back quick-

clamping lever. The quick-clamping lever pivots back powerfully due to the spring force.

Fig. 3 Fastening element

Tool holder

Quick-clamping lever

180°