Ruinet Utility User Manual

 

 

Page 14 of 46

 

 

 

 

 

Parameter

Description

 

 

The number of times a cache Map Descriptor containing outdated

 

Cache - Created

data has been polled resulting in the creation of a new cache Map

 

 

Descriptor. See Error! Reference source not found.

 

Cache - Bumped

The number of expired cache blocks. See Error! Reference

 

source not found.

 

 

 

 

Writes are never cached - the external device is put on hold while

 

Pex Write Thru

the FieldServer resends the message to the PLC and waits for the

 

response. When the FieldServer receives the response from the

 

 

PLC it in turn responds to the external device. This operation is

 

 

counted as a PEX Write thru.

 

 

The maximum time that the FieldServer has taken since the last

 

Server Response Max

reset to receive a message from an external device, poll the PLC

 

and respond to the external device. The SCADA Hold Timeout

 

 

 

 

parameter should be set higher than this limit

 

 

This is the average time that the FieldServer has taken since the

 

Server Response Avg

last reset to receive a message from an external device, poll the

 

PLC and respond to the external device. Reconfigure if response

 

 

 

 

times are slow.

 

Link Control

 

 

 

Who-Is-Router-To-Network

BACnet specific – see Driver Manual.

 

I-Am-Router-To-Network

 

 

 

 

Reject-Msg-To-Network

 

 

 

Messages Reconstructed

Metasys Specific – see Driver Manual.

 

Unsupported Property

The driver encountered an unsupported property in a message.

 

Unsolicited Messages Recd

A message was received without the driver polling for it.

 

Single Write

A write data message containing a single data element.

 

Single Item Read

A read data message requesting a single data element.

 

Block Write

A write message containing a block of data elements.

 

Block Read

A read message requesting a block of data elements.

 

Sequence Error

Messages containing sequence numbers received out of

 

sequence.

 

 

 

Data Object Startup

Data requested from a node in start-up mode.

 

Expedite Read

The number of Map Descriptors given the highest priority to

 

Expedite Write

complete a read/write first.

 

Fasttrack Read

The number of Map Descriptors given a higher priority to complete

 

Fasttrack Write

a read/write as soon as possible.

 

Fasttrack Overrun Read

The number of times the buffer holding fasttrack read/write Map

 

Fasttrack Overrun Write

Descriptors overflowed.

 

Max Read Response Time

Maximum/Minimum/Average time in seconds that passed before a

 

Min Read Response Time

response was received to a read message sent by a driver acting

 

Avg Read Response Time

as a Client.

 

Max Write Response Time

Maximum/Minimum/Average time in seconds that passed before a

 

Min Write Response Time

response was received to a write message sent by a driver acting

 

Avg Write Response Time

as a client.

 

Max Passthru Response Time

Maximum/Minimum/Average time in seconds to receive a

 

Min Passthru Response Time

response to a poll sent using the Passthru mechanism.