McQuay Micro Tech Open Protocol Driver Manual

 

Page 27 of 35

 

 

 

 

 

 

 

 

 

 

 

 

 

Array

Read/

 

 

Number

Base

Device

 

 

 

 

Write/

Field Name

Scaling9

 

 

 

 

Location

of Bytes

Address

 

 

 

 

 

 

 

 

 

 

Both

 

 

 

 

Method

 

 

 

 

82

b

Economizer (Air) Method

1

0x083B

1

 

 

 

 

83

b

Economizer (Water) Changeover Temperature Offset

1

0x091A

1

 

 

 

 

84

b

Fan On Heating Setpoint

1

0x0939

1

 

 

 

 

85

b

Head Pressure Deadband

1

0x08E1

1

 

 

 

 

86

b

Head Pressure Setpoint

1

0x093A

1

 

 

 

 

87

b

Heating Control Deadband

1

0x0894

1

 

 

 

 

88

b

Heating Control Setpoint

1

0x0905

1

 

 

 

 

89

b

Heating Supply Deadband

1

0x0871

1

 

 

 

 

90

b

Heating Supply Setpoint

1

0x0914

1

 

 

 

 

91

b

Humidity Control Type

1

0x0947

1

 

 

 

 

92

b

Humidity Deadband

1

0x094C

1

 

 

 

 

93

b

Humidity Setpoint

1

0x094B

1

 

 

 

 

94

b

Low Entering H20 Comp. Lockout Differential

1

0x092C

1

 

 

 

 

95

b

Low Entering Water Compressor Lockout Setpoint

1

0x092B

1

 

 

 

 

96

b

Min Vane Position/Fan Speed

1

0x0951

1

 

 

 

 

97

b

Minimum Outdoor Air Damper Position

1

0x0934

1

 

 

 

 

98

b

Minimum Supply Air Temperature Control

1

0x0919

1

 

 

 

 

99

b

Unoccupied Cooling Space Differential

1

0x0904

1

 

 

 

 

100

b

Unoccupied Cooling Space Setpoint

1

0x0903

1

 

 

 

 

101

b

Unoccupied Heating Space Differential

1

0x0902

1

 

 

 

 

102

b

Unoccupied Heating Space Setpoint

1

0x0901

1

 

 

 

 

103

b

Water Flow Signal

1

0x0444

1

 

 

Appendix A.3.

 

McQuay Equipment Types recognized by the driver.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Code

 

 

Description

 

 

 

 

 

 

 

200CFC

 

 

200 Series Centrifugal Chiller

 

 

 

 

 

 

 

100CFC

 

 

100 Series Centrifugal Chiller

 

 

 

 

 

 

 

001ASC

 

 

Air Screw Chiller

 

 

 

 

 

 

 

000SCU

 

 

Self Contained Unit

 

 

 

 

 

 

 

0050RPC

 

 

Reciprocating Chiller

 

 

 

 

 

Appendix A.4. Direct Addressing

Direct addressing allows data to be read from the McQuay device when the field name is unknown. McQuay specifies the addresses in hexadecimal notation but they must be specified in the CSV file in decimal format. For example, to read McQuay address 0x0400, the address in the CSV file must be entered as 1024.

If reading multiple addressing at once (i.e. if the length is greater than 1) it may be necessary to adjust the timeout for the Map Descriptor.

It is possible to read multiple addresses using one Map Descriptor; however, it is only possible to write to a single address.

The following Map Descriptor parameters will need to be defined in addition to those described in section 4.4.

FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldServer.com Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: support@fieldServer.com

Page 27
Image 27
FieldServer FS-8700-80 Appendix A.3 McQuay Equipment Types recognized by the driver, Appendix A.4. Direct Addressing