Fisher & Paykel CG122, CG244 Installation instructions, Gas rate summary, Adjustment screw

Models: CG122 CG244

1 96
Download 96 pages 42.36 Kb
Page 21
Image 21
3Adjust the minimum burner setting:

Installation instructions

19

US CA

3Adjust the minimum burner setting:

When changing from one gas type to another, the minimum valve output must also be correct, considering that in this position the flame must be about 5⁄32” (4 mm) long and must remain lit even when the knob is turned quickly from the maximum to the minimum position.

The adjustment is performed with the burner lit, as follows:

Turn the knob to the minimum position. Remove the knob.

Turn the adjustment screw to the correct setting with a screwdriver (Fig.17).

Adjustment screw

Fig. 17 Adjusting the minimum burner setting

For LP/Propane gas, tighten the adjustment screw completely.

4Re-test for leaks:

Repeat the steps under ‘Leak-testing the cooktop’.

5Fill in/affix the gas conversion labels:

After completing the gas conversion, fill in the gas conversion labels (supplied with the conversion kit).

Affix the adhesive/polyester label near the model/serial rating plate on the underside of the basepan.

Affix the paper label into the appropriate frame at the front of this manual, under the duplicate data (model/serial/rating) plate.

Gas rate summary

 

CG122 models

 

Nominal

Reduced

LP/PROPANE

NATURAL GAS

 

 

 

power

power

11” W.C.P.

4” W.C.P.

 

 

 

 

 

 

Burners

 

BTU/hr

BTU/hr

injector

By-pass

injector

By-pass

 

 

 

[1/100 mm]

[1/100 mm]

[1/100 mm]

[1/100 mm]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Semi-rapid

6000

1500

72

34

118

adjustable

 

 

 

 

 

 

 

 

 

 

 

 

Rapid

10000

2000

94

44

155

adjustable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CG244 models

 

Nominal

Reduced

LP/PROPANE

NATURAL GAS

 

 

 

power

power

11” W.C.P.

4” W.C.P.

 

 

 

 

 

 

Burners

 

BTU/hr

BTU/hr

injector

By-pass

injector

By-pass

 

 

 

[1/100 mm]

[1/100 mm]

[1/100 mm]

[1/100 mm]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Auxiliary

 

3500

1000

55

27

90

adjustable

 

 

 

 

 

 

 

 

 

 

 

 

Semi-rapid

 

6000

1500

72

34

118

adjustable

 

 

 

 

 

 

 

 

 

 

 

 

Triple-ring wok

 

11500

5200

100

65

165

adjustable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 21
Image 21
Fisher & Paykel CG122 Installation instructions, Gas rate summary, Adjustment screw, 3Adjust the minimum burner setting