Fisher & Paykel DD602I manual General Information, Section, 1 PREPARATION, Page DD02

Models: DD602I DD602

1 24
Download 24 pages 61.67 Kb
Page 3
Image 3
GENERAL INFORMATION

GENERAL INFORMATION

STEP 1.1 PREPARATION

NOTE TO THE INSTALLER

νBe sure to leave these instructions with the Customer.

νEnsure this appliance is properly grounded.

NOTE TO THE CONSUMER

νKeep these Installation Instructions with your Use & Care Manual for future reference.

IMPORTANT

νRead these Instructions completely and carefully.

νObserve all governing Codes and Ordinances.

WARNING

νThese Instructions are intended as a guide only.

νIt is the responsibility of the plumber and electrician to ensure that each installation complies with all Codes and Ordinances.

νInstallation of this DishDrawer requires basic mechanical and electrical skills.

νThe installer is responsible for the DishDrawer installation.

Improper installation is not covered under the Express Warranty Form.

IMPORTANT

νAt the completion of the DishDrawer installation, the Installer must perform Final Checks as per Section 8 of these Installation Instructions.

νEnsure the DishDrawer enclosure is prepared for installation.

νRemove all packaging and materials supplied with the DishDrawer.

νIf you have any questions concerning the installation of this DishDrawer, contact:

Fisher & Paykel Customer Care Centre

27 Hubble

TOLL FREE 1-888-9-FNP USA

Irvine

TOLL FREE 1-888-9-36 7 872

CA 92618

Fax (949) 790 8911

USA

WWW.FISHERPAYKEL.COM

 

STEP 1.2 PRODUCT SPECIFICATIONS & CAVITY DIMENSIONS

SECTION 1

WARNING

Before installing the DishDrawer, remove the house fuse or open the circuit breaker.

Ensure all water connections are turned

OFF.

STEP 1.1 PREPARATION WARNING

The DishDrawer MUST be installed to allow for future removal from the enclosure if service is required.

Electrical

110-120 VAC

(Water pressure below 7 p.s.i.

 

3 pin socket outlet

(50 kpa) may require the electronics

Drying

Residual Heat

 

to be re-programmed by a Service

 

& Fan Assisted

 

Person at the time of installation)

Water Connection

Recommended Hot

 

 

 

 

140°F Max. (60°C)

 

 

Water Pressure

Maximum 139 p.s.i. (960 kpa)

 

 

 

Minimum 4.3 p.s.i. (30 kpa)

 

 

Page DD_02
Page 3
Image 3
Fisher & Paykel DD602I manual General Information, Section, 1 PREPARATION, 2 PRODUCT SPECIFICATIONS & CAVITY DIMENSIONS