9.7Filter Plate Removal

March 2004

Manual 599082

9.7Filter Plate Removal

9.7.1Remove the lower racks from the tub.

9.7.2Remove the drain filter assembly.

9.7.3Rotate the filter plate locknut anti-clockwise to release the filter plate from the rotor assembly.

9.7.4Lift the filter plate clear.

9.7.5Refit in reverse manner.

9.8Rotor Assembly Removal

9.8.1Remove filter plate as per instructions 9.7.

9.8.2Rotate the rotor locking ring anti clockwise to release it from the motor assembly and lift out.

9.8.3The rotor assembly is not serviceable.

9.8.4Refit in reverse manner.

9.9Wiring Cover Removal

9.9.1Remove the drawer front as per instructions in 9.1.

9.9.2With the tub opened release the tub clips and push back the

drawer rails as explained in 9.2.2.

9.9.3 Carefully release the four wiring cover clips from the front lower section of the tub taking care not to damage them.

9.9.4Release the three clips on the underside of the tub which retain the wiring cover.

9.9.5 Pull the tub fully open and lift it up at the front (this makes it easier to remove the wiring cover from the rear of the tub).

9.9.6 The wiring cover may now be carefully moved forward to release it from the rear of the tub.

9.9.7To reassemble first ensure that the wiring harnesses, drain

hose and fill hose are clipped into their correct position. 9.9.8 Then refit in reverse manner