Model 187 & 189

Users Manual

Measuring Frequency

Frequency is the number of cycles a signal completes each second. The meter measures the frequency of a voltage or current signal by counting the number of times the signal crosses a threshold level each second.

Figure 3-13 highlights the function selections that allow frequency measurement.

To measure frequency, select an appropriate function, connect the meter signal source, and press N.

The meter autoranges to one of four frequency ranges:

500.00Hz, 5.0000 kHz, 50.000 kHz, and 999.99 kHz. Figure 3-14 shows a typical frequency display.

 

nS

mV

F

ac+dc

C

V

A

mA

ac+dc

mV

A

dB

 

V

A

mA

dB

ac+dc

OFF

A

 

ac+dc

 

VIEW MEM

 

CLEAR MEM

tc021f.eps

Figure 3-13. Functions Allowing Frequency

Measurement

3-22

Page 57
Image 57