Fortress Bridge: Command-Line Interface
112
[GW]>
show sac
SwabSerialNum:24743196
SwabConfigID:0
SwabSACRole:SAC_SLAVE
SwabSACState:SAC_INIT4SWAB
SwabSACVer:SAC_VER_PEGASUS_ARCH1
10 Log off the new Bridge’s CLI and disconnect the Console
port cable.
11 Log onto the Bridge CLI of the master/root Bridge and add
the new Bridge’s serial number to the master Bridge’s SAC
Peer list, with the add command:
[GW]>
add sp 24743196
[OK]
If you are adding multiple Bridges, enter their serial
numbers separated by commas, without spaces.
12 Execute the set sac start command:
[GW]>
set sac start
[OK] Started SAC process successfully
When the SAC process starts, you can observe the master/
root Bridge’s front-panel Stat1 LED flash amber and its
Stat2 LED light solid amber. As the new Bridge receives the
SAC parameters, its Stat1 and Stat2 LEDs flash amber in
unison.
NOTE: