1.6Adjusting the Pilot Flame
Non-CE Gas Valves
1.For Non-CE Gas Valves, remove the screw from the pilot adjustment screw hole on the gas valve.
2.Using a small, flat-tipped screwdriver, turn the pilot adjustment screw counterclockwise to in- crease the length of the flame or clockwise to decrease the length of the flame. Adjust flame to a length of 1 to 1½ inches (25 to 38mm).
3.Reinstall the pilot adjustment screw cap.
The pilot adjustment screw on the Non-CE Honeywell valve is under this screw.
CE Gas Valves
Using a small, flat-tipped screwdriver, turn the pilot adjustment screw counterclockwise to increase the length of the flame or clockwise to decrease the length of the flame. Adjust flame to a length of 25 to 38mm.
The pilot adjustment on the CE valve is here.
1.7Calibrating the Thermostat Control
On Standard MJ35 Fryers
1.Fill the frypot to the lower OIL-LEVEL line with cooking oil. If solid shortening is used, it must be tightly packed into the frypot before starting calibration procedure.
2.Light the pilot. (Refer to Chapter 3 of the Installation and Operation Manual, P/N 819-5776 for detailed lighting instructions.)
3.Insert a good grade thermometer or pyrometer into the frypot, about one inch from the thermostat.
4.Set the thermostat to 325°F (162°C).
5.Let the burner cycle on and off three times.
1-3