Frymaster 35 Series manual 1.6Adjusting the Pilot Flame Non-CEGas Valves, CE Gas Valves

Models: 35 Series

1 40
Download 40 pages 11.88 Kb
Page 7
Image 7
1.6Adjusting the Pilot Flame

1.6Adjusting the Pilot Flame

Non-CE Gas Valves

1.For Non-CE Gas Valves, remove the screw from the pilot adjustment screw hole on the gas valve.

2.Using a small, flat-tipped screwdriver, turn the pilot adjustment screw counterclockwise to in- crease the length of the flame or clockwise to decrease the length of the flame. Adjust flame to a length of 1 to 1½ inches (25 to 38mm).

3.Reinstall the pilot adjustment screw cap.

The pilot adjustment screw on the Non-CE Honeywell valve is under this screw.

CE Gas Valves

Using a small, flat-tipped screwdriver, turn the pilot adjustment screw counterclockwise to increase the length of the flame or clockwise to decrease the length of the flame. Adjust flame to a length of 25 to 38mm.

The pilot adjustment on the CE valve is here.

1.7Calibrating the Thermostat Control

On Standard MJ35 Fryers

1.Fill the frypot to the lower OIL-LEVEL line with cooking oil. If solid shortening is used, it must be tightly packed into the frypot before starting calibration procedure.

2.Light the pilot. (Refer to Chapter 3 of the Installation and Operation Manual, P/N 819-5776 for detailed lighting instructions.)

3.Insert a good grade thermometer or pyrometer into the frypot, about one inch from the thermostat.

4.Set the thermostat to 325°F (162°C).

5.Let the burner cycle on and off three times.

1-3