35 SERIES GAS FRYERS
CHAPTER 1: SERVICE PROCEDURES
1.1Functional Description
The 35 Series fryers contain a welded steel (stainless or
The flames originate from orifices in a
35 Series Orifice Sizes
Gas | Inches | Millimeters |
Natural (G20/25) | 0.0669 | 1.70mm |
LP (G31) | 0.0413 | 1.05mm |
Gas flow to the manifold is regulated by an electromechanical gas valve. This series of fryers is equipped with a millivolt gas valve and all models use a pilot ignition system.
Pilot Ignition System
The pilot ignition system is made up of the pilot orifice, pilot hood, and a thermopile. The pilot serves two purposes: light the burner and heat the thermopile. In operation, the thermopile is in con- tact with the pilot flame and generates millivolts. The millivolt output passes through a normally closed
Control Options
The temperature control knob on FM/MJ35 fryers is located behind the hinged front panel, out of sight. On FM/MJ35G fryers, the knob is exposed on the face of the front panel. The MJ35G model may be equipped with optional basket lifts. The basket lift option requires an electrical power supply.
Thermostats
Fryers in this series are equipped with an adjustable controlling (operating) thermostat. The temperature at which the thermostat opens and closes is adjusted by turning the temperature control knob referenced above. The controlling thermostat used in the 35 Series fryers is sensitive to
All 35 Series fryers are equipped with a