Press the Boil-Mode switch  to reset the timer to 195°F (91°C).

CANCELING THE MELT-CYCLE

Manual background DANGER

Do not cancel the melt-cycle mode if using solid shortening!

The melt-cycle is designed to prevent scorching shortening and overheating the frypot or elements while gradually melting blocks of shortening. The timer automatically starts the fryer in the melt- cycle mode and remains in this mode until the temperature in the frypot reaches 180°F (82°C) or the melt-cycle is canceled by the operator. If you are NOT using solid shortening, you may cancel the melt cycle feature.

To cancel the melt-cycle on a full-pot unit, press the right Basket Lift switch Manual background. On a split-pot unit, press the left Basket Lift switch Manual background to cancel the left frypot, or the right Basket Lift switch Manual background to cancel the right frypot.

USING THE BOIL-OUT FEATURE

Press the Boil-Mode switch Manual background to reset the timer to 195°F (91°C).

On Full-Pot Units, the controller will maintain the frypot temperature at 195°F (91°C) until either ON/OFF Manual background switch is pressed to turn the controller off.

On Split-Pot Units, the controller will maintain both frypot temperatures at 195°F (91°C) until the frypots are turned off. To turn off the left frypot, press the left ON/OFF Manual backgroundManual backgroundManual backgroundManual backgroundManual background switch. To turn off the right frypot, press the right ON/OFF Manual background switch.