PROBLEM |
| PROBABLE CAUSES | CORRECTIVE ACTION | |
|
|
| A. If available, substitute a | |
Display shows |
|
| computer/controller known to be | |
, | A. Failed computer/controller. | working for the suspect | ||
| ||||
heating indicator |
| computer/controller. If the fryer | ||
cycles on and off |
| functions correctly, order | ||
normally, but |
| replacement from FASC. | ||
burners will not |
| B. If available, substitute a harness | ||
light and blower is | B. Damaged computer/controller | known to be good for the suspect | ||
not running. | wiring harness. | harness. If the fryer functions | ||
|
| correctly, order replacement | ||
|
|
| ||
|
|
| harness from FASC. | |
Fryer is slow coming |
|
| ||
out of melt cycle. |
|
| ||
Display shows | Dirty or obstructed combustion air | Clean and adjust per instructions | ||
a short time | blower. | in Chapter 5 of this manual. | ||
after coming out of |
|
| ||
melt cycle. |
|
| ||
Fryer is operating |
|
| ||
normally, but | Dirty or obstructed combustion air | Clean and adjust per instructions | ||
recovery is slow | blower. | in Chapter 5 of this manual. | ||
when cooking. |
|
| ||
Fryer is operating | A. Dirty or obstructed combustion air | A. Clean and adjust per instructions | ||
normally, but | blower. | in Chapter 5 of this manual. | ||
B. Dirty or obstructed gas valve vent | B. Clean per instructions in Chapter | |||
produces a popping | ||||
sound when burners | tube | 5 of this manual. | ||
C. Malfunctioning combustion air | C. If blower is slow to come up to | |||
ignite. | ||||
|
| blower. | speed, contact FASC for service. | |
Display shows |
| If available, substitute a | ||
| computer/controller known to be | |||
and alarm |
| |||
| working for the suspect | |||
sounds, but fryer | Failed computer/controller. | |||
computer/controller. If the fryer | ||||
operates normally |
| |||
| functions correctly, order | |||
(false alarm). |
| |||
| replacement from FASC. | |||
|
|
| ||
Computer will not |
| If available, substitute a | ||
| computer/controller known to be | |||
go into program |
| |||
| working for the suspect | |||
mode or some | Failed computer/controller. | |||
computer/controller. If the fryer | ||||
buttons do not |
| |||
| functions correctly, order | |||
actuate. |
| |||
| replacement from FASC. | |||
|
|
| ||
Heat indicator is on |
|
| ||
and blower is | Blown fuse on interface board or | Replace fuse. | ||
running, but burner | ignition module. | |||
| ||||
will not ignite. |
|
|