Frymaster 8195991 operation manual Problem, Probable Causes, Corrective Action

Models: 8195991

1 50
Download 50 pages 32.9 Kb
Page 44
Image 44
Manual background

PROBLEM

 

PROBABLE CAUSES

CORRECTIVE ACTION

 

 

 

A. If available, substitute a

Display shows

 

 

computer/controller known to be

,

A. Failed computer/controller.

working for the suspect

 

heating indicator

 

computer/controller. If the fryer

cycles on and off

 

functions correctly, order

normally, but

 

replacement from FASC.

burners will not

 

B. If available, substitute a harness

light and blower is

B. Damaged computer/controller

known to be good for the suspect

not running.

wiring harness.

harness. If the fryer functions

 

 

correctly, order replacement

 

 

 

 

 

 

harness from FASC.

Fryer is slow coming

 

 

out of melt cycle.

 

 

Display shows

Dirty or obstructed combustion air

Clean and adjust per instructions

a short time

blower.

in Chapter 5 of this manual.

after coming out of

 

 

melt cycle.

 

 

Fryer is operating

 

 

normally, but

Dirty or obstructed combustion air

Clean and adjust per instructions

recovery is slow

blower.

in Chapter 5 of this manual.

when cooking.

 

 

Fryer is operating

A. Dirty or obstructed combustion air

A. Clean and adjust per instructions

normally, but

blower.

in Chapter 5 of this manual.

B. Dirty or obstructed gas valve vent

B. Clean per instructions in Chapter

produces a popping

sound when burners

tube (non-CE fryers only).

5 of this manual.

C. Malfunctioning combustion air

C. If blower is slow to come up to

ignite.

 

 

blower.

speed, contact FASC for service.

Display shows

 

If available, substitute a

 

computer/controller known to be

and alarm

 

 

working for the suspect

sounds, but fryer

Failed computer/controller.

computer/controller. If the fryer

operates normally

 

 

functions correctly, order

(false alarm).

 

 

replacement from FASC.

 

 

 

Computer will not

 

If available, substitute a

 

computer/controller known to be

go into program

 

 

working for the suspect

mode or some

Failed computer/controller.

computer/controller. If the fryer

buttons do not

 

 

functions correctly, order

actuate.

 

 

replacement from FASC.

 

 

 

Heat indicator is on

 

 

and blower is

Blown fuse on interface board or

Replace fuse.

running, but burner

ignition module.

 

will not ignite.

 

 

6-3

Page 44
Image 44
Frymaster 8195991 operation manual Problem, Probable Causes, Corrective Action