Manuals
/
Frymaster
/
Kitchen Appliance
/
Fryer
Frymaster
8195991 operation manual This Page Intentionally Left Blank
Models:
8195991
1
19
50
50
Download
50 pages
32.9 Kb
16
17
18
19
20
21
22
23
<
>
Troubleshooting
Install
Maintenance
Problem
Filter Pump Reset Switch
Preparation for Use with the Magnasol Filter Assembly
Shipping Damage Claim Procedure
Cleaning
Safety
Snap the optional Power Shower into position
Page 19
Image 19
THIS PAGE INTENTIONALLY LEFT BLANK
Page 18
Page 20
Page 19
Image 19
Page 18
Page 20
Contents
Pro H55-Series Gas Fryers
24-Hour Service Hotline
8195991
SEPTEMBER
NOTICE TO U.S. CUSTOMERS
DANGER
CHAPTER 6 Operator Troubleshooting
TABLE OF CONTENTS
CHAPTER 2 Installation Instructions
CHAPTER 5 Preventive Maintenance
THIS PAGE INTENTIONALLY LEFT BLANK
PRO H55 SERIES GAS FRYER CHAPTER 1 GENERAL INFORMATION
1.2 Parts Ordering and Service Information
1.1 Applicability and Validity
1.4 European Community CE Specific Information
1.3 Safety Information
Non-CE Standard for Incoming Gas Pressures
DANGER
QUALIFIED AND/OR AUTHORIZED OPERATING PERSONNEL
1.6 Installation, Operating, and Service Personnel
1.5 Equipment Description
1.7 Definitions
QUALIFIED SERVICE PERSONNEL
1.8 Shipping Damage Claim Procedure
What to do if your equipment arrives damaged
QUALIFIED INSTALLATION PERSONNEL
DANGER
PRO H55 SERIES GAS FRYER CHAPTER 2 INSTALLATION INSTRUCTIONS
2.1 General Installation Requirements
DANGER
DANGER
One of the most important considerations of efficient fryer operation is ventilation. Make sure the fryer is installed so that products of combustion are removed efficiently, and that the kitchen ventilation system does not produce drafts that interfere with burner operation
DANGER
AUSTRALIAN REQUIREMENTS
2.2 Caster/Leg Installation
2.3 Pre-Connection Preparations DANGER
DANGER
4. Test the fryer electrical system
DANGER
DANGER
2.4 Connection to Gas Line DANGER
Non-CE Standard for Incoming Gas Pressures
DANGER
4 or more
Required airflow for the combustion air supply is 2m3/h per kW
Gas Connection Pipe Sizes
CE Approved Gas Categories by Country
DANGER
1. Connect the quick-disconnect hose to the fryer quick-disconnect fitting under the front of the fryer and to the building gas line
Non-CE Gas Conversion Kits
2.5 Converting to Another Gas Type DANGER
CE Gas Conversion Kits for Units with Gas Valve
CE GAS CONVERSION INSTRUCTIONS
THIS PAGE INTENTIONALLY LEFT BLANK
PRO H55 SERIES GAS FRYER CHAPTER 3 OPERATING INSTRUCTIONS
3.2 Start-Up Procedure
3.1 Controller Operation and Programming
Lighting the Fryer
3.4 Shutting the Fryer Down
3.3 Boiling Out the Frypot
For Non-CE Fryers
THIS PAGE INTENTIONALLY LEFT BLANK
DANGER
PRO H55 SERIES GAS FRYERS CHAPTER 4 FILTRATION INSTRUCTIONS
4.1 Draining and Manual Filtering DANGER
DANGER
DANGER
4.2 Preparing the Built-In Filtration System for Use
DANGER
4.2.1 Preparation for Use with Filter Paper or Filter Pad
use filter powder with the pad
4.2.2 Preparation for Use with the Magnasol Filter Assembly
DANGER
4.3 Operation of the Filter DANGER
DANGER
DANGER
DANGER
Snap the optional Power Shower into position
DANGER
Filter Pump Reset Switch
Step 2 - Separate the outer screens and grid
4.4 Disassembly and Reassembly of the Magnasol Filter Dissassembly
Cleaning
Reassembly
Steps 1 and 2 - Stack outer screens and insert edges into frame
4.5 Draining and Disposing of Waste Oil
DANGER
Handle
4.6 Using the Optional Rear-Discharge Oil Disposal
WEEKLY CHECKS AND SERVICE
PRO H55 SERIES GAS FRYERS CHAPTER 5 PREVENTIVE MAINTENANCE
5.1 Fryer Preventive Maintenance Checks and Service
DAILY CHECKS AND SERVICE
DANGER
Clean Filter Pan, Detachable Parts and Accessories
Check Calibration of Analog Controller Thermostat Control Knob
MONTHLY CHECKS AND SERVICE
This check applies only to units equipped with Analog Controllers
Authorized Service Center for assistance
Clean Combustion Air Blower Assembly
QUARTERLY CHECKS AND SERVICE
5. Reinstall the blower shield or shield assembly
Check Burner Manifold Pressure
SEMI-ANNUAL CHECKS AND SERVICE
Never use the filter pan to transport old oil to the disposal area
Clean Gas Valve Vent Tube
DANGER
5.3 Annual/Periodic System Inspection
Fryer
CLEAN-OUT PLUGS
Built-In Filtration System
DANGER
PRO H55 SERIES GAS FRYERS CHAPTER 6 OPERATOR TROUBLESHOOTING
6.1 Introduction
Before calling a servicer or the Frymaster HOTLINE
PROBABLE CAUSES
PROBLEM
CORRECTIVE ACTION
PROBABLE CAUSES
PROBLEM
CORRECTIVE ACTION
PROBABLE CAUSES
6.3 Troubleshooting Fryers with Solid State Analog Controller
PROBLEM
PROBLEM
PROBABLE CAUSES
PROBLEM
CORRECTIVE ACTION
PROBABLE CAUSES
6.4 Troubleshooting the Built-in Filtration System
PROBLEM
PROBLEM
CORRECTIVE ACTION
PROBLEM
Power Shower is not
PROBABLE CAUSES
PROBABLE CAUSES
6.5 Troubleshooting the Basket Lift
PROBLEM
PROBLEM
819-5991
SERVICE HOTLINE
Shipping Address 8700 Line Avenue, Shreveport, Louisiana
TEL 1-318-865-1711 FAX Parts 1-318-219-7140 FAX Tech Support