Frymaster 8195991 Troubleshooting Fryers with Solid State Analog Controller, Problem

Models: 8195991

1 50
Download 50 pages 32.9 Kb
Page 45
Image 45
6.3Troubleshooting Fryers with Solid State (Analog) Controller

PROBLEM

PROBABLE CAUSES

CORRECTIVE ACTION

Heat indicator off

 

If available, substitute a

 

computer/controller known to be

upon initial startup.

 

 

working for the suspect

Display shows

Failed computer/controller.

computer/controller. If the fryer

or with alarm

 

 

functions correctly, order

sounding.

 

 

replacement from FASC.

 

 

6.3Troubleshooting Fryers with Solid State (Analog) Controller

PROBLEM

PROBABLE CAUSES

 

CORRECTIVE ACTION

 

 

A.

Verify that the fryer is plugged in

 

A. No power to fryer.

 

and that the circuit breaker is not

 

 

 

tripped.

 

 

B. If available, substitute a harness

Power switch ON, no

B. Damaged controller wiring

 

known to be good for the suspect

 

harness. If the fryer functions

lights on controller,

harness.

 

correctly, order replacement

 

 

fryer does not heat.

 

 

harness from FASC.

 

 

C.

If available, substitute a controller

 

 

 

known to be working for the

 

C. Failed controller.

 

suspect controller. If the fryer

 

 

 

functions correctly, order

 

 

 

replacement from FASC.

Power light ON,

 

 

If available, substitute a harness

 

 

known to be good for the suspect

trouble light ON,

Damaged controller wiring

 

 

harness. If the fryer functions

heating mode light

harness.

 

 

correctly, order replacement

OFF.

 

 

 

 

harness from FASC.

 

 

 

 

 

A. Press the ON/OFF switch off,

 

A. Drain valve not fully closed.

 

close the drain valve(s)

 

 

completely, then press the

 

 

 

 

 

 

ON/OFF switch on.

 

 

 

 

B. Gas valve is not turned on.

B. Turn the gas valve knob to the

 

 

ON position.

 

 

 

Power light ON,

 

C. Verify that any in-line manual

trouble light ON,

C. Manual gas shut off valve closed.

 

shut off valve is open. Verify that

heating mode light

 

 

gas main cut off valve is open.

 

D.

Verify that the quick-disconnect

ON. Burners do not

D. Improperly connected quick-

ignite.

disconnect fitting on gas line.

 

fitting on the flexible gas line is

 

 

 

firmly connected to the fryer.

 

 

E. Verify that combustion air blower

 

 

 

is running. If not, call FASC for

 

E. Obstructed or failed combustion

 

service. If combustion air blower

 

air blower.

 

is functional, clean and adjust per

 

 

 

instructions in Chapter 5 of this

 

 

 

manual.

 

6-4

 

 

Page 45